Compur Statox 501 IR LC - Infrared detection of combustible gases. 
 
The Statox 501 IR LC sensor head consists of an increased safety (EEx e) terminal box and 
a sensor with integrated electronics. The sensor operates with IR absorption principle. The 
supply voltage required is the same as for a catalytic sensor. Its signal output is also 
identical to a catalytic sensor, therefore it can be directly connected to the 501 Controller. 
 
The important technical advantages of an infrared gas detector are now available for almost 
the same low price as a catalytic gas detector. The big advantage: As this product has the 
same energy requirements and signal  output as common gas detection systems, the Statox 
501 IR LC can be used to upgrade existing systems wherever the catalytic sensor did not do 
the job. 
 
The Statox 501 IR LC it is a reasonable alternative to catalytic sensors wherever gas 
detection equipment is used to monitor hydrocarbons. The standard ex works calibration is 
Methane. 
 
 
Technical data 
 
Detectable gases 
Hydrocarbons 
Measuring range 
 
0 – 100 % L.E.L. Methane 
Measuring principle   
IR- absorption, NDIR 2-channel 
Detection limit 
2 % L.E.L. Methane 
Response time 
 
t
90 
< 30 s 
Operating temperature 
- 20 to + 60°C 
Humidity 
0 – 95 % r. H. 
Pressure 
 
700 – 1300 hPa 
Power supply 
3 - 5,0 V DC 
Current consumption 
app. 80 mA 
Connection 
3 –wire 
Operation 
with Statox 501 Controller or 
comparable supply 
Weight 
0,58 kg 
Dimensions 
110 x 130 x 60 mm HxWxD 
(4,3 x 5,1 x 2,4 in.) 
Material 
Die cast aluminum, coated 
Protection class 
IP 54 
Ex approval 
EEx de IIC T4 
 
 
 
 
 
 
 
 
 
 
Statox 501  Controller 
Compur Monitors GmbH & Co. KG 
Weissenseestraße 101 
D-81539 München 
Tel.: 089/62038-268 
Fax: 089/62038-184 
Email: compur@compur.de  
Internet: 
http://www.compur.com
 
Specifications are subject to change without notice, and are provided only for comparison of products. The 
conditions, under which our products are used, are beyond our control. Therefore, the user must fully test our 
products and/or information to determine suitability for any intended use, application, condition or situation. All 
information is given without warranty or guarantee. Compur Monitors disclaims any liability, negligence or otherwise, 
incurred in connection with the use of the products and information. Any statement or recommendation not contained 
herein is unauthorized and shall not bind Compur Monitors. Nothing herein shall be construed as a recommendation 
to use any product in conflict with patents covering any material or device or its use. No licence is implied or in fact 
granted under the claims of any patent. Instruments are manufactured by Compur Monitors GmbH & Co. KG, Munich.  
The General Conditions of Supply and Service of Compur Monitors GmbH & Co. KG are applicable. 01/2006