Sierra Monitor Corporation 2006 产品宣传页
Rev. A2-8-23-07 © 2007 by Sierra Monitor Corporation
Model 2001 Combustibles Gas Monitor
The Model 2001 can detect a wide range of combus-
tibles. Typical applications include combustible gas
monitoring in basements near waste dumps, manhole,
tanks, parking garages and vehicle maintenance facili-
ties, laboratories, chemical plants, and more.
tibles. Typical applications include combustible gas
monitoring in basements near waste dumps, manhole,
tanks, parking garages and vehicle maintenance facili-
ties, laboratories, chemical plants, and more.
OUTPUT:
0.5 AMP dry contact. 100 VDC, 130 VAC
Nominal 5 volts DC, source 25 mA, SAFE and
ALARM signals 70 dB buzer.
TTL interface to Model 2102 Alarm Panel is
user configurable.
Nominal 5 volts DC, source 25 mA, SAFE and
ALARM signals 70 dB buzer.
TTL interface to Model 2102 Alarm Panel is
user configurable.
RESPONSE TIME:
Model 2001
Model 2001
Less than 30 seconds
Model 2003
For 50 ppm alarm, if 50 ppm H
2
S is present,
1-4 min. If >250 ppm H
2
S is present, 30-60
seconds.
Model 2006
Less than 30 seconds
PERIODIC
MAINTENANCE:
MAINTENANCE:
None, other than routine calibration
OPERATING
TEMPERATURE
TEMPERATURE
-4
o
F to158
o
F
RANGE:
-20°C to 70°C
ENCLOSURE
MATERIAL:
MATERIAL:
Aluminum
SIZE:
3.7 x 2.2 x 1.1 in. (9.4 x 5.7 x 2.8 cm)
WEIGHT:
3.8 oz (108 g)
APPROVAL:
UL 60950
Sierra Monitor Corporation 1991 Tarob Ct. Milpitas, CA 95035 (408) 262-6611 800-727-4377 FAX: (408) 262-9042
Visit our Web site at: www.sierramonitor.com E-Mail: sierra@sierramonitor.com
Model 2006 Carbon Monoxide Monitor
The Model 2006 Carbon Monoxide Gas Sensor Mod-
ule can be used to provide an early warning of CO
accumulation in tanks, laboratories, chemical plants,
parking garages, vehicle test facilities and more.
ule can be used to provide an early warning of CO
accumulation in tanks, laboratories, chemical plants,
parking garages, vehicle test facilities and more.
ORDERING INFORMATION
Combustible Gas
2001-00
Hydrogen Sulfide
2003-00
Carbon Monoxide
2006-00
Model 2003 Hydrogen Sulfide Monitor
The Model 2003 can be used in such typical applica-
tions as waste water treatment plants, laboratories and
chemical plants.
tions as waste water treatment plants, laboratories and
chemical plants.
SPECIFICATIONS
INDICATORS:
Visual:
Visual:
Green LED for Monitor “ON"/Safe
Red LED for Alarm
LEDs oscillate on/off for sensor failure
Red LED for Alarm
LEDs oscillate on/off for sensor failure
Audible:
Sustained alarm tone for as long
as gas is present. Interrupted tone or sensor
failure.
as gas is present. Interrupted tone or sensor
failure.
SENSOR TYPE:
Solid-State Metal Oxide Semiconductor
RANGE;
(at 50% relative humidity)
Model 2001
300-2,000 ppm Hydrogen
500-10,000 ppm Methane
500-10,000 ppm Methane
Model 2003
10-50 ppm Hydrogen Sulfide (H
2
S)
Model 2006
50-500 ppm Carbon Monoxide (CO)
FACTORY ALARM
SETPOINT:
Model 2001
SETPOINT:
Model 2001
1000 ppm Methane
Model 2003
50 ppm H
2
S
Model 2006
100 ppm CO
INPUT:
9 - 24VDC (+1V), 250 mA
Plug-in 120 VAC AC/DC Power Supply is
provided
Plug-in 120 VAC AC/DC Power Supply is
provided
Gas Sensor Monitors