Napoleon Fireplaces GDS60N 用户手册

下载
页码 52
50
W415-0788 / A / 09.22.09
Main burner and 
pilot cycles on 
and off.
GS600 ONLY
Venting is spilling.
 
-
Test with spill switch bypassed. Replace if defective.
 
-
Check for vent blockage.
GDS600 ONLY
GDS600 ONLY
42.7_3
SYMPTOM
PROBLEM
TEST SOLUTION
White / grey fi lm 
forms.
Sulphur from fuel is being 
deposited on glass, logs or 
combustion chamber
surfaces.
 
-
Clean the glass with a recommended gas appliance 
glass cleaner. DO NOT CLEAN GLASS WHEN 
HOT.
 
-
If deposits are not cleaned off regularly, the glass 
may become permanently marked.
Flames are very 
aggressive.
Door is ajar.
 
-
Tighten door clamps.
Venting action is too great.
 
-
Restrict vent exit with restrictor plate. See 
“RESTRICTING VENTS” section.
Main burner fl ame 
is a blue, lazy, 
transparent
fl ame.
Blockage in vent.
 
-
Remove blockage. In really cold conditions, ice 
buildup may occur on the terminal and should be 
removed. 
Compromised venting.
 
-
Check venting system parameters (seal, length, 
rise, etc.).
GLASS EMBERS ONLY:
Too many glass embers.
 
-
Re-distribute glass embers so that only a single 
layer is over top of the burner tube.
Main burner goes 
out: pilot goes out.
Vent recirculation.
 
-
Check joint seals and installation.