BLOWER SYSTEM  
The Blower System consists of a ON / OFF 
rocker switch, a variable speed blower speed 
control switch (rheostat) located on the right 
side panel, a thermally activated switch (fan 
disc) and 4 axial blowers.  
 
When starting a fire, leave the blower system 
off until the insert is thoroughly heated (approx. 
30 minutes after start up). 
 
The blowers can be operated in one of the fol-
lowing manners: 
 
Auto:
 Turn rocker switch to the off position ( 
O” = off, ““ = on).  Turn the rheostat to the on 
position by rotating the rheostat dial clockwise 
until it clicks. When the insert warms up (110
° 
F), the blower will automatically turn on (adjust 
rheostat dial to the desired speed setting). 
When the insert cools down (90
° F), the blow-
ers will automatically turn off. 
Manual:  Turn rocker switch to the on (  ) 
position and adjust rheostat dial to the desired 
speed. The blowers will have to be manually 
turned off by rotating the rheostat dial counter-
clockwise until it clicks. 
 
BLOWER SPECIFICATIONS
: 115 V, 60 Hz, 
two axial blowers - .42 amps each, 125 CFM 
each. Blower system has a flexible electrical 
cord that must be electrically grounded per lo-
cal codes or NEC, ANSI / NFPA 70-latest edi-
tion. Do not route the power cord under or in 
front of the appliance. 
 
Blower System Controls 
 
Located on right side of door at bottom of panel 
 
 
WIRING DIAGRAM 
 
 
 
POWER FLOW DIAGRAM 
 
 
CAUTION:  BURNING THE INSERT AT A HIGH BURN RATE 
FOR EXTENDED PERIODS WITHOUT RUNNING THE BLOW-
ERS CAN CAUSE EXCESSIVE TEMPERATURES RESULTING 
IN OVERFIRING DAMAGE TO THE APPLIANCE. EXCESSIVE 
HEAT WILL CAUSE THE PROPELLERS ON THE BLOWERS TO 
MELT.  IF THIS OCCURS, REPLACE PROPELLERS AND RE-
VIEW THESE INSTRUCTIONS FOR PROPER OPERATION 
(PROPELLER PART / CATALOG #410-25-3. SOME PEOPLE 
PREFER METAL PROPELLERS, WHICH ARE AVAILABLE 
THROUGH GRAINGER, STOCK #2C953. BE ADVISED THAT 
THESE ARE NOISIER THAN STANDARD PLASTIC BLADES). 
OVERFIRING DAMAGE IS NOT COVERED UNDER THE 5 YEAR 
PRORATED WARRANTY. 
 
WARNING:  THIS APPLIANCE IS EQUIPPED WITH A BLOWER 
SYSTEM WHICH HAS A FLEXIBLE ELECTRICAL POWER 
CORD WITH A THREE-PRONG (GROUNDING) PLUG FOR 
YOUR PROTECTION AGAINST SHOCK HAZARD AND 
SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY 
GROUNDED THREE-PRONG RECEPTACLE PER LOCAL 
CODES OR NEC, ANSI / NFPA 70 - LATEST EDITION.  DO NOT 
CUT OR REMOVE THE GROUNDING PRONG FROM THE 
POWER CORD PLUG. DO NOT ROUTE POWER CORD UNDER 
OR IN FRONT OF APPLIANCE.