NOTE:  Installation and repair should be performed by a qualified service person.  The 
appliance should be inspected annually by a qualified professional service person.  More 
frequent inspections and cleanings may be required due to excessive lint from carpeting, 
bedding material, pet hair, etc.  It is imperative that the control compartment, burners and 
circulating air passage ways of the appliance be kept clean. 
 
Provide adequate clearances around air openings and adequate accessibility clearance for 
service and proper operation.  Never obstruct the front openings of the appliance. 
 
This appliance is designed to operate on natural or propane gas only.  The use of other fuels or 
combination of fuels will degrade the performance of this system.  The gas input of this 
appliance is 22,000 BTU/HR for natural gas and 22,000 BTU/HR for propane gas models. 
 
Children and adults should be alerted to the hazards of high surface temperatures and 
should stay away to avoid burns or clothing ignition.  Young children should be carefully 
supervised when they are in the same room as the appliance.  Clothing or other flammable 
material should not be placed on or near the appliance. 
 
Any safety screen or guard removed for servicing this appliance must be replaced prior to 
operating the appliance. 
 
WARNING 
  
  
Do not operate with the glass door removed, cracked, or broken.  Replacement of the glass 
should be done by a licensed or qualified service person. 
 
 
Do not use this appliance if any part has been under water.  Immediately call a qualified service 
technician to inspect the appliance and to replace any parts of the control system and any gas 
controls which have been under water. 
 
Minimum inlet gas pressure is 5" Water Column for natural gas and 10.5" Water Column for 
propane for the purpose of input adjustment. 
 
Maximum inlet gas supply pressure is 10.5" Water Column for natural gas and 14" Water 
Column for propane. 
 
The appliance must be isolated from the gas supply piping system (by closing its individual 
manual shut-off valve) during any pressure testing of the gas supply piping system at test 
pressures equal to or less than 1/2 psig (3.5kPa). 
 
This appliance and its individual shut-off valve must be disconnected from the gas supply 
piping system during any pressure testing of that system at pressures in excess of 1/2 psig 
(3.5kPa).