Regency L676E-LP 用户手册

下载
页码 48
Regency
®
 L676E Direct Vent Gas Fireplace
21
INST
ALLA
TION
Vertical Venting with Two (2) 90
o
 Elbows
Vertical Venting with Three (3) 90
o
 Elbows
Option  V 
    H 
V + V1 
     A) 
2' Min.  2' Max.  3' Min. 
     B) 
2' Min.  10' Max.  6' Min. 
     C) 
3' Min.  6' Max.  4' Min. 
     D) 
4' Min.  7' Max.  5' Min. 
     E) 
5' Min.  8' Max.  6' Min.
One 90
o
 elbow = Two 45
o
 elbows.
With these options, max. total pipe 
length is 30 feet with min. of 6 feet 
total vertical and max. 10 feet total 
horizontal.
Please note min. 1 foot between 
90
o
 elbows is required.
Option        V 
H + H1  V + V1
     A) 
2' Min.  2' Max.   4' Min.
     B) 
3' Min.  4' Max.   6' Min.
     C) 
4' Min.  5' Max.   7' Min.
     D) 
5' Min.  6' Max.   8' Min.
     E) 
6' Min.  8' Max.   9' Min.
One 90
o
 elbow = Two 45
o
 elbows.
With these options, max. total 
pipe length is 30 feet with min. 
of 9 feet total vertical and max. 
8 feet total horizontal.
Please note min. 1 foot 
between 90
o
 elbows is 
required.
VENT RESTRICTOR SETTING:
Vent restrictor must be at Set 0 for both NG and LP.
VENT RESTRICTOR SETTING:
Vent restrictor must be at Set 0 for both NG and LP.