Regency L900-NG 用户手册

下载
页码 56
Regency
®
 L900 Direct Vent Gas Fireplace
40
OPERA
TION
OPERATING INSTRUCTIONS
NOTE: The control knob is located on the  
right hand side of the fi rebox behind the 
right side exterior brick panel.
1)  Push in gas control knob slightly and turn 
clockwise to “OFF”. Knob cannot be turned 
from “PILOT” to “OFF” unless knob is pushed 
in slightly.  Do not force.
 
2)  Wait fi ve (5) minutes  to clear out any gas. 
3)  Turn knob  on gas control counterclockwise        
to “PILOT”.
4)  Push in control knob all the way and hold  in 
until the pilot lights up. Continue to hold the 
control knob in for about 20 seconds after 
the pilot is lit. Release knob and it will pop 
back up. Pilot should remain lit. If it goes out, 
repeat steps 1) to 4).  If knob does not pop 
up when released, stop and immediately 
call your service technician or gas supplier. 
If the pilot will not stay lit after several tries, 
turn the gas control knob to “OFF” and call 
your service technician or gas supplier.
5)  Turn gas control knob counterclock-wise to 
“ON”.
6)  Turn the unit on with the remote. 
 
NOTE: When using the remote control refer 
to the FireWizard manual for instructions.
SHUTDOWN 
PROCEDURE
1)  Turn the 3-way switch to the "OFF" 
position.
2)  Turn the main gas control clockwise to the 
"OFF" position to turn off the pilot.
3)  Turn off all electric power to appliance if 
service is to be performed.
NORMAL OPERATING 
SOUNDS OF 
GAS APPLIANCES
It is possible that you will hear some sounds 
from your gas appliance. This is perfectly normal 
due to the fact that there are various gauges 
and types of steel used within your appliance. 
Listed below are some examples. All are normal 
operating sounds 
and should not be considered 
as defects in your appliance.
Burner Tray: 
The burner tray is positioned directly under the 
burner  tube and logs and is made of a different 
gauge material from the rest of the fi rebox and 
body. Therefore, the varying thicknesses of steel 
will expand and contract at slightly different 
rates which can cause "ticking" and "cracking" 
sounds. You should also be aware that as there 
are temperature changes within the unit these 
sounds will likely re-occur. Again, this is normal 
for steel fi reboxes.
Pilot Flame:
While the pilot fl ame is on it can make a very 
slight "whisper" sound.
Gas Control Valve: 
As the gas control valve turns ON and OFF, a 
dull clicking sound may be audible, this is normal 
operation of a gas regulator or valve.
Unit Body/Firebox: 
Different types and thicknesses of steel will 
expand and contract at different rates resulting 
in some "cracking" and "ticking" sounds will be 
heard throughout the cycling process.
OPERATION DURING 
POWER OUTAGE
Important:
If the unit is not used for a prolonged period of 
time, we recommend turning the 3-way switch on 
the manual control panel to "Off" (manual control 
panel is located on the left hand side of the fi rebox 
behind the left side exterior brick panel).
Also see "Lighting Plate Instructions" for details 
on how to turn off the pilot.
Rear Burner  
Switch
3-way Switch
Manual Control Panel
Located on the left hand side of the 
fi rebox behind the exterior brick panel.
When in "Remote" position;
In the event of a power failure, if the 3-way switch 
is in the "Remote" position, the unit cannot be 
operated with the Remote Control until after 
power is restored.
To operate unit during a power failure;
NOTE: Both burners when on will operate at the 
lowest fl ame setting. The BTU's for NG 
will be 32,000 and 27,000 for LP.
Front Burner Operation:
1)  Remove the left side exterior brick panel to 
access to the Manual Control Panel.
2)  To turn on the front burner, change the 3-way 
switch to "Manual" position.
Rear Burner Operation:
1)  Remove the left side exterior brick panel to 
access to the Manual Control Panel.
2)  To turn on the rear burner, change the Rear 
Burner Switch to the "On" position. Changing 
the switch to the "Off" postion will turn the 
rear burner off.
 
Note: The rear burner will only operate if the 
front burner is on.
When in "Manual" position;
In the event of a power failure, if the 3-way switch 
is in the "Manual" position the front buner will 
remain on at the lowest setting and will remain 
on when power resumes. If the rear burner is 
not in use, to operate see "Rear Burner Opera-
tion" above.
Both burners when on will operate at the lowest 
fl ame setting. The BTU's for NG will be 32,000 
and 27,000 for LP.
When power resumes the unit will remain on at 
the lowest setting until reset using the remote 
control.
NOTE: When power is restored, reset the 
3-way switch on the Manual Control 
Panel to the "Remote" position to be 
able to use the FireWizard
TM
 Remote 
Control.