Regency P48-2 用户手册

下载
页码 52
Regency
®
 P48-2 Zero Clearance Direct Vent Gas Fireplace
16
L676 & L900 Direct Vent Fireplace
IMPORTANT NOTE
•  A Vent Guard is required when the AstroCap is installed above grade at 7 feet or lower.
•  The Simpson Dura-Vent and Selkirk Direct Temp horizontal termination caps cannot be used in any applications.
•  Only the AstroCap XL and Snorkels are certifi ed for horizontal terminations.
NOTE: Horizontal runs of vent must be level, or have a 1/4 inch rise for every 1 foot of run towards 
the termination. Never allow the vent to run downward.  This could cause high temperatures and 
may present a possible fi re hazard.
Offset Pipe Selection:
Use this table to determine offset pipe lengths.
Pipe Length
5” x 8” Venting
Run (X)
Rise (Y)
0”(0mm)
5-11/16”(144mm)
15-5/16”(389mm)
6”(152mm)
8-13/16”(224mm)
18-7/16”(468mm)
9”(229mm)
10-15/16”(278mm)
20-9/16”(522mm)
12”(305mm)
13”(330mm)
22-11/16”(576mm)
24”(610mm)
21-7/16”(697mm)
31-1/16”(789mm)
36”(914mm)
29-13/16”(757mm)
39-7/16”(1002mm)
48”(1219mm)
38-1/4”(972mm)
47-7/8”(1216mm)
L
Y
X
FPI
946-604/P
Simpson Direct Vent Vent Guard (Optional)
946-623/P
AstroCap XL Horizontal Cap
770-994
Rigid Pipe Adapter (Must use with all Rigid Piping)
946-506/P
Vent Guard (Optional)
946-625
Vinyl Siding Standoff - AstroCap XL
Description
Simpson
Direct Vent Pro
®
Simpson 
Direct Vent GS
®
Discontinued
Selkirk
 
Direct-Temp™
Metal-Fab
®
Sure Seal
Round Support / Radiation Sheild
N/A
N/A
N/A
N/A
Flat Flashing
N/A
N/A
N/A
N/A
Attic Insulation Shield 12”
58DVA-IS - N/A from FPI
58DVA-IS - N/A from FPI
N/A
N/A
Basic Horizontal Termination Kit (A)
N/A
N/A
5DT-HKA
N/A
Horizontal Termination Kit (B)
58DVA-KHA 
N/A
5DT-HKB
N/A
Vertical Termination Kit
58DVA-VCH
1291
5DT-VKC
N/A
High Wind Vertical Cap
N/A
N/A
N/A
N/A
High Wind Horizontal Cap
DISC.
1285
N/A
N/A
Horizontal Square Termination Cap
N/A
1284
5DT-HHC
5DHT
Vertical Termination Cap
N/A
N/A
5DT-HVC
5DVT
Storm Collar
58DVA-SC
1253
5DT-SC
5DSC
Adjustable Flashing, 0/12-6/12
58DVA-F6
1243
5DT-AF6
5DF
Adjustable Flashing, 6/12-12/12
58DVA-F12
1243S
5DT-AF12
5DF-12
Vinyl Siding Standoff
58DVA-VSS
1250
5DT-VS
5DVS
Vinyl Siding Shield Plate
N/A
N/A
5DT-VSP
N/A
Snorkel Termination 14”
58DVA-SNK14
1282
5DT-ST14
5DST14
Snorkel Termination 36”
N/A
1281
5DT-ST36
5DST36
Restrictor Disk
58DVA-RD
N/A
N/A
N/A
Colinear Flex Liner Adapter (3” Ø)
N/A
N/A
N/A
N/A
Components from different Manufacturers may not be mixed.  Not All Rigid Pipe components are available directly from FPI.
*NOTE:  When using Metal-Fab Sure Seal Rigid Piping please note that either the Adaptor (5DDA) or 90º Starter Elbow  
 
(5D90A) must be used in conjunction with FPI Rigid Pipe Adaptor (770-994).
For specifi c instructions or details on particular 
venting components please visit the following 
websites:
Simpson Direct Vent Pro:  www.duravent.com
Selkirk Direct-Temp:  www.selkirkcorp.com
Metal-Fab Sure Seal:  www.mtlfab.com
INSTALLATION