U35 FPI Direct Vent Gas Insert
Diagram 4
Diagram 5
Diagram 3
INSTALLATION 
9)  Attach the brass trim to the faceplate by 
drilling a 1/8" hole through into the faceplate 
using the hole in the trim as a guide. Fasten 
the trim to the faceplate panels using the 
plated screws. Diagram 4.
10) Attach the faceplate panels to the insert 
body using the 4 remaining black screws. 
Diagram 5.
11) Push the Regency logo plate into the 
two holes in the bottom left corner of the 
faceplate. See Diagram 4.
Diagram 6
Use the hook to pull the spring out until you 
can put the hook into the slot on the bottom 
door bracket. Repeat for 2nd spring.  See 
diagram 8.
 
Diagram 8
Diagram 7
STANDARD 
FLUSH DOOR
The standard fl ush door comes with a black 
frame. To install the frame, simply hook the top 
door fl ange onto the top of the unit and swing 
the door towards the unit, diagram 6. Be careful 
that the glass gasket does not roll up; there must 
be a gap between 
the gasket and the 
door lip to ensure 
that the door sits 
securely on the 
unit. Diagram 7.
To remove the fl ush door, reverse the above 
steps.
NOTE: The chain must rest on TOP of the gas 
inlet pipe never under it.
OPTIONAL FLUSH TRIM
Attach 2 round magnets to the back of the top 
trim piece and the other 2 to the bottom trim 
piece, then attach trim to the top and bottom 
of Flush door.
FLUSH LOUVERS
2)  Install the Spring Hinges on the left and right 
side of the bottom of the Firebox using 2 
screws per hinge.
3)  Place the Bottom Louver near the hinge. Flip 
hinge over the Bottom Louver and secure 
using 3 screws.
Bottom Louver
Hinge
Location
1)  The top louver is held in place by friction fi t, 
if the louver needs to be adjusted; bend the 
bracket out as shown in the diagram.