IMPORTANT MESSAGE  
The FPI Gas Insert must be installed in  
accordance with these instructions. Carefully 
read all the instructions in this manual fi rst. 
Consult the building authority having jurisdiction 
to determine the need for a permit prior to starting 
the installation.
NOTE:  Failure to follow the instructions could 
cause a malfunction of the heater which could 
result in death, serious bodily injury, and/or 
property damage.  Failure to follow these 
instructions may also void your fi re  insurance 
and/or warranty. 
FOR YOUR SAFETY
This appliance requires air for proper combustion.  
Always provide adequate combustion and 
ventilation air.  Follow instructions and information 
in CAN/CGA B149 (in Canada) or the National 
Fuel Gas Code ANSI Z223.1 (in the USA), 
regarding requirements for combustion and 
ventilation air.
GAS PRESSURE 
TESTING
The appliance must be isolated from the gas 
supply piping system by closing its individual 
manual shut off valve during any pressure testing 
of the gas supply piping system at test pressures 
equal to or less than
1/2 psig. (3.45 kPa).
SPECIFICATIONS
At pressures over 1/2 psig, the pipe to the unit 
must be disconnected.
Gas Input Capacity:  
 
Natural Gas  35,000 Btu/h
 Propane 
35,000 
Btu/h
Min. Input (Fan Off)
 
Natural Gas  17,500 Btu/h
 Propane 
17,500 
Btu/h
Max. Output  
 
   
   Fan On 
  Fan Off
  Natural Gas  26,800 Btu/h  26,300 Btu/h
  Propane 
27,500 Btu/h  27,000 Btu/h
Fuels:  Approved for use with both natural gas, 
and propane. Approved as is for use at 0' to 
4,500' (0-1370m).
Electrical:  120V   A.C. system.
Circulation Fan:  Variable speed, 127 CFM.
Log Set:  Ceramic fi bre, 3 per set.
Vent System: 3" co-linear aluminum fl ex.
INSTALLATION
The effi ciency rating of the appliance is a 
product thermal effi ciency rating determined 
under continuous operating conditions and 
was determined independent of any installed 
system.
    
INSTALLATION 
INTO A SOLID FUEL 
BURNING FIREPLACE 
OR FACTORY BUILT 
FIREPLACE
The U35 Gas Inserts have been tested and 
approved to be vented into any masonry 
fireplace or  approved solid fuel burning 
factory built fi replace that will allow the insert 
to physically fi t into the fi rebox. Refer to the 
"Minimum Fireplace Dimensions" section for 
minimum fi replace clearances.
If the factory built fi replace* height is too low 
for your Insert, you may remove the smoke 
baffl e plate and damper from the factory 
built  fi replace as long as these items are 
saved and are reinstalled in the event that 
the Insert is removed. NOTE: Any alterations 
made to the listed solid fuel burning factory 
built  fi replace may void the listing of the 
fi replace.
*Check with your local inspector before 
commencing with this installation.
BEFORE YOU START
Safe installation and operation of this appliance 
requires common sense, however,  we are 
required by the Canadian Safety Standards 
and ANSI Standards to make you aware of 
the following:
General Safety Information
1)  The appliance installation must conform 
with local codes or in the absence of 
local codes, with CAN/CGA B149 (in 
Canada) or the National Fuel Gas Code 
ANSI Z223.1 in the U.S.A. This appliance 
should be installed by a qualifi ed gas fi tter 
technician only.
2)  Installation and repair should be done by 
a qualifi ed service person.  
3)  The  appliance should be inspected before 
use and at least annually by a professional 
service person. More frequent cleaning 
may be required due to excessive lint 
from carpeting, bedding material, animal 
hair, etc.  It is imperative that control 
compartments, burners and circulating 
air passageways of the appliance be kept 
clean. 
4)  See general construction and assembly 
instructions. This appliance may only be 
installed in a vented, noncombustible 
fi replace.
5)  This appliance is Listed for bedroom  
installations when used with a Listed Millivolt 
Thermostat. Some areas may have further 
requirements, check local codes before 
installation.
6)  Always connect this insert to a vent system 
venting to the outside of the building 
envelope. Never vent  to another room or 
inside a building.  Make sure that the vent 
is properly sized and is of adequate height 
to provide the proper draft.  
7)  Inspect the venting system annually for 
blockage and any signs of deterioration.   
8)  Any glass removed for servicing must be 
replaced prior to operating the appliance.  
9)  WARNING: Failure to position the parts 
in accordance with the diagrams in 
this manual or failure to use only parts 
specifi cally approved with this appliance 
may result in property damage or personal 
injury.
10) To prevent  injury, do not allow anyone who 
is unfamiliar with the operation to use the 
fi replace.  
11) Due to high temperatures, the appliance 
should be located out of high traffi c areas and 
away from furniture and draperies. Children 
and adults should be alerted to the hazards 
of high surface temperatures, especially 
the  fi replace glass and gold trims, and 
should stay away to avoid burns or clothing 
ignition. Young children should be carefully  
supervised when they are in the same room 
as the appliance. Clothing or other fl ammable 
material should not be placed on or near the 
appliance.
Emissions from burning  wood or gas could 
contain chemicals known to the State of 
California to  cause cancer, birth defects or 
other reproductive harm.
Installer must mechanically attach the supplied 
label to the inside of the fi rebox of the fi replace 
into which the gas fi replace insert is installed.
"WARNING: This fi replace has been converted 
for use with a gas fi replace insert only and 
cannot be used for burning wood or solid fuels 
unless all original parts have been replaced, 
and the fi replace re-approved by the authority 
having jurisdiction."