6
INSTALLATION
Clearances for Bay or Flush Front
NOTE: The minimum fl oor clearance must 
be maintained from the top surface of the 
carpeting, tile, etc.
Minimum Clearance from Top of Unit to:
 Mantel* 
Minimum 
7" (177mm) 
 Ceiling 
from top of unit. 
32"   (1016mm)
Side Wall Clearance
  Bay or Flush Front
 6" 
(152mm)
 
Horizontal Flue Clearances
 Top 
2"  (51mm)
 Side 
1-1/2" 
(38mm) 
 Bottom 
1-1/2" 
(38mm)
Vertical Flue Clearances 1-1/4" 
(32mm)
Alcove Clearances**:
 Max. 
Depth 36" 
(914mm)
 Min. 
Width 48" 
1219mm)
 Min. 
Height 72" 
1829mm)
* see mantle clearance instructions 
(Refer to section "Combustible Mantels" & 
"Mantel Leg Clearances."
CLEARANCES
The clearances listed below are Minimum 
distances unless otherwise stated:
A major cause of chimney related fi res  is 
failure to maintain required clearances (air 
space) to combustible materials. It is of the 
greatest importance that this fi replace and 
fl ue system be installed only in accordance 
with these instructions.
Clearance to Combustibles from:
  Back
 0" 
(0mm) 
    Side 0" 
(0mm) 
  Floor 0" 
(0mm) 
 
Diagram 1
LOCATING YOUR 
GAS FIREPLACE
1)  When selecting a location for your stove, 
ensure that the clearances outlined on this 
page are met.
2)  P r o v i d e   a d e q u a t e   c l e a r a n c e s   f o r 
servicing.
3)  The appliance must be installed on a fl at, 
solid, continuous surface (e.g. wood, metal, 
concrete). This may be the fl oor, or raised up 
on a platform to enhance its visual impact. 
If the appliance is going to be installed 
on carpeting, combustible linoleum tile or 
other combustible material other than wood 
fl ooring, the appliance must be installed on 
a metal or wood panel extending the full 
width and depth of the appliance.
4)  The P36 Co Axial Flue Gas Fireplace can 
be installed in a recessed position or framed 
out into the room as in A, B, C, D. See
 Diagram 
1.
MANUFACTURED 
MOBILE HOME 
ADDITIONAL 
REQUIREMENTS
1)  Ensure that structural members are not cut 
or weakened during installation.
2)  Ensure proper grounding using the #8 ground 
lug provided. See section "Wiring."
A) Flat 
on 
Wall
B)  Flat on Wall Corner
C) Recessed 
into 
Wall/Alcove
D) Corner   
5)  This appliance is Listed for bedroom 
 
installations when used with a Listed Millivolt 
Thermostat. Some areas may have further 
requirements, check local codes before 
installation.
6)  The P36 Co Axial Flue Gas Fireplace is 
approved for alcove installations, which 
meet the clearances listed on this page.
7)  We recommend that you plan your installation 
on paper using exact measurements for 
clearances and floor protection before 
actually installing this appliance. Have an 
authorized inspector, dealer, or installer 
review your plans before installation.
Note:   For  fl ue terminations see section 
" E x t e r i o r   F l u e   Te r m i n a t i o n 
Locations."
WARNING
Fire hazard is an 
extreme risk 
if these clearances 
are not adhered to.