INSTALLATION
18)
  Verify that if the conversion is from NG to LPG, the screw  must 
be re-assembled with the red o-ring visible (Fig. 5).
19)
  Re-assemble the black protection cap (Fig. 6).
LPG Configuration
Red o-ring visible
Fig.5 
20)
  Reverse steps 8 - 1.
21)  
Attach the label "This unit has been converted to LPG" near or on 
top of the serial # decal. 
Fig. 6
WARNING!
Also check that the pilot and main 
burner injectors are appropriate for 
the gas type.
22)
  Replace yellow "NG" label with red "LPG" label.
Fig. 1
Fig.2 
Fig.4 
Fig.3 
17)
  Using the Allen wrench as shown in 
Fig.4, rotate the screw clockwise until 
snug, do not overtighten.
14)
  Insert a 5/32” or 4mm Allen wrench into the hexagonal key-way 
of the screw (Fig. 2), rotate it counter-clockwise until it is free and 
extract it.
15)
  Check that the screw is clean and if necessary remove dirt.
16)
  Flip the screw (Fig. 3).
WARNING!
Do not over tighten the screw. 
Recommended to
grip the wrench by the short side.
12)
  Turn control knob to the “OFF” position.
13)
  Remove the black protection cap by hand from the hi-low knob 
(Fig.1).
Cap
Red O-ring