 P90 Zero Clearance Direct Vent Gas Fireplace
11
VENTING
FPI Direct  Vent System (Flex) Horizontal Terminations Only
These venting systems, in combination with the P90 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by 
Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in the "Exterior Vent 
Termination Locations" section.
FPI Direct Vent (Flex) System Termination 
Kit (Part # 946-515) includes all the parts 
needed to install the P90 with a maximum 
run of 4 feet.
1)  6-7/8" dia. fl exible liner (4 ft. length)
2)  4" dia. fl exible liner (4 ft. length)
3)  spring spacers (4)
4) thimble 
(2)
5)  AstroCap termination cap (1)
6) screws 
(12)
7)  tube of Mill Pac (1)
8) plated 
screws 
(8)
9)  screws #8 x 1-1/2"  Drill Point, Stainless 
Steel (4)
If a  longer run is needed, the FPI Direct Vent 
system (Flex) kit is 946-516 which includes 
all the parts needed to install the P90 with a 
maximum 10' run.
1)  6-7/8" dia. fl exible liner (10 ft. length)
2)  4" dia. fl exible liner (10 ft. length)
3)  spring spacers (7)
4) thimble 
(2)
5)  AstroCap termination cap (1)
6) screws 
(12)
7)  tube of Mill Pac (1)
8) plated 
screws 
(8)
9)  screws #8 x 1-1/2" Drill Point, Stainless Steel 
(4)
Notes: 
1)  Liner sections should be 
 
continuous without any joints or 
seams.
2)  Only Flex pipe purchased from FPI may 
be used for Flex installations.
3)  Horizontal vent must be supported every 
3 feet.
INSTALLATION