The  Focus  will  operate  without  electrical 
power.  This model has a Millivolt gas control 
which uses the pilot flame to generate enough 
electricity  to  operate  the  main  burners.  This 
appliance when equipped with a blower, must 
be  electrically  connected  and  grounded  in 
accordance with local codes or in the absence 
of  local  codes,  with  the  current  CSA  C22.1 
CANADIAN ELECTRICAL CODE Part 1, SAFETY 
STANDARDS FOR ELECTRICAL INSTALLATIONS, 
OR THE NATIONAL ELECTRICAL CODE ANSI / 
NFPA 70 in the U.S.
WARNING:  Electrical  grounding  instructions. 
This appliance is equipped with a three-prong 
(grounding)  plug  for  your  protection  against 
shock hazard, and should be plugged directly 
into  a  properly  grounded  three-prong  outlet.  
DO  NOT  cut  or  remove  the  grounding  prong 
from this plug.
Table 3.  Recommended Thermostat 
Wire Size.
Wire Size
Max. Length
14 gauge
100 ft  (30.48 m)
16 gauge
60 ft   (18.29 m)
18 gauge
40 ft   (12.00 m)
20 gauge
25 ft   (7.62 m)
22 gauge
18 ft   (5.49 m)
COOL / HEAT
PROGRAM
DOWN
UP
70 ° F
70 ° F
ON
OF
F
Optional
Remote
Control
Purple
Grey
Optional
Wall Switch
Optional
Thermostat
Pilot
Adjustment
Screw
ON/OFF/REMOTE
Thermostat Switch
Blue
Thermopile
Thermocouple
Manifold
Pressure
Tap
Inlet
Pressure
Tap
Gas
Control
Valve
Figure 25: Wiring of a Thermostat.
Figure 24: Focus Wiring Diagram.
Initial Installation
QUALIFIED INSTALLERS ONLY
E
LECTRICAL
 R
EQUIREMENTS
:
CAUTION:  Label  all  wires  prior  to  disconnection  when  servicing  controls.    Wiring  errors  can  cause 
improper and dangerous operation.  Verify proper operation after servicing.