Trouble Shooting
Problem
Possible Cause
Solution
The  main  burner 
does  not  ignite 
when called for.
The gas valve may not be on.
• Check that the gas control knob is in the “ON” position.
Thermostat is not calling for 
heat.
• Adjust the thermostat several degrees above ambient temperature.
Problem with gas valve.
• Use a DC voltmeter to measure the voltage across the TPTH and 
TP terminals. Main operator voltage: Open circuit ≥ 325mV Closed 
circuit ≥ 100mV
• If voltage is not present, check the control circuit for proper 
operation.
• If proper control system voltage is present, replace the gas control.
Spark will not 
light the pilot 
after repeatedly 
pressing the 
spark ignitor.
Defective piezo ignitor.
• Check connections to ignitor.
• If ignitor connections are good but no spark, replace ignitor.
Broken spark electrode.
• Check for broken ceramic insulation, replace electrode if broken.
Misaligned spark electrode.
• If spark is not arcing from electrode to pilot, loosen the screws on the 
pilot base adjust and tighten.
Pilot will not 
remain lit.
Problem with thermocouple 
circuit.
• Check for proper connection of the thermocouple to the rear of the 
valve. If loose, fully tighten.
• Check pilot for full flame impingement around thermocouple.  If flame 
is too small, check gas pressure, adjust pilot rate screw, check pilot 
head for damage.
• Check thermocouple voltage at valve. It must be greater than 5 mV.  
If low, replace thermocouple.
Air in gas line (pilot dies while 
knob is depressed).
• Bleed line.
• Check gas line pressure.
• Contact dealer.
Burners will not 
remain lit.
Problem with thermopile 
circuit.
• Check gas line pressure .
• Check for flame impingement on thermopile. If low, see “Pilot will not 
remain lit”.
• Check thermopile for minimum of 300 mV when burner is switched 
on.
• Check wiring to thermostat for breaks.
BV ONLY: Check for spillage at draft hood that may trip spill switch
Flame lifting
Leak in vent pipe
• Check for leaks in vent connections.
Improper vent configuration
• Check vent configuration with manual.
Terminal may be recirculating 
flue gases
• Check to see if terminal is on correctly.
• May need to install high wind termination cap.
• Contact dealer.
Glass fogs up
Normal Condition: after the appliance warms up the glass will clear.
**Due to additives in gas, glass may get hazy during operation** Clean as needed.
Blue Flames
Normal during start up: flames will yellow as the fireplace heats up.
Flames are 
burning “dirty” or 
sooting
Flame impingement
• Check log positioning.
• Increase primary air by opening the venturi shutter and/or by 
opening the vent restrictor.
See also “Burners will not remain lit.”
Remote control 
doesn’t work
Problem with the remote
• One or more of the batteries are dead. See remote control 
instructions.
Problem with fireplace
• The on/off switch is turned to OFF.
• The gas control valve is turned to PILOT or OFF.
• The pilot has gone out.
BV ONLY: 
Insufficient air 
for combustion
• Air tight house.
•  A  vacuum  in  room  due  to 
other air-moving device.
• Supply make up air to the unit.
22