cap assembly. It is important that the vent pipe 
extend  into  the  vent  cap  a  sufficient  distance 
with  a  minimum  of  11⁄4”  (3.2  cm)  overlap. 
Secure  the  connection  between  the  vent  cap 
pipe  and  the  vent  cap  by  attaching  the  two 
sheet  metal  straps  extending  from  the  vent 
cap  assembly  into  the  outer  wall  of  the  vent 
pipe. Use the two sheet metal screws provided 
to  connect  the  straps  to  the  vent  pipe.  Bend 
any remaining portion of the sheet metal straps 
back  towards  the  vent  cap,  so  the  decorative 
wall  thimble  will  conceal  it  (see  left  image  in 
Figure 14).
STEP 7. Slide the decorative wall thimble up to the wall 
surface  and  attach  with  the  screws  provided. 
Apply decorative brass or chrome trim if desired 
(see right image in Figure 14). 
NOTES:  
(1) 
The four wood screws provided should be replaced 
with  the  appropriate  fasteners  for  stucco,  brick, 
concrete, or other types of siding.
(2)  For  buildings  with  vinyl  siding,  a  vinyl  siding 
standoff, should be installed between the vent cap 
and  the  exterior  wall  (see  Figure  15).  Attach  the 
vinyl siding standoff to the horizontal termination. 
The  vinyl  siding  standoff  prevents  excessive  heat 
from possibly melting the vinyl siding material. Note 
that the horizontal vent termination bolts onto the 
flat portion of the vinyl siding standoff (shaded area 
in Figure 15), so that an air space will exist between 
the wall and the vent termination.
Initial Installation
QUALIFIED INSTALLERS ONLY
Figure 15: Installing Vent Cap with Vinyl Siding 
Stand-Off.
Figure 16: Installing Horizontal Vent Termination.
STEP 3. With the pipe attached to the stove in the correct location, mark the wall for a 10” (25.4 cm) x 
10” (25.4 cm) square hole (refer to Figure 13). The center of the square hole should match the 
center line of the horizontal pipe. Cut and frame the 10” (25.4 cm) x 10” (25.4 cm) hole in the 
exterior wall where the vent will be terminated. Refer to Figure 8. If the wall being penetrated 
is constructed of non-combustible material i.e. masonry or concrete, a 7 inches (17.8 cm) hole 
is acceptable.
STEP 4. Position the horizontal vent termination in the center of the 10” (25.4 cm) x 10” (25.4 cm) 
hole, and attach to the exterior wall with the four screws provided. Before attaching the vent 
termination to the exterior wall, run a bead of non-hardening mastic around the edges, so as to 
make a seal between the termination and the wall. The arrow on the vent termination should be 
pointing up, insure that the proper clearances to combustible materials are maintained.
STEP 5. Before connecting the horizontal run of the vent pipe to the vent termination, slide the black 
decorative wall thimble cover over the vent pipe.
STEP 6. Slide the appliance and vent assembly towards the wall, carefully inserting the vent pipe into the