Secondary Installation
Figure 39: Once the logs are in 
place the embers can be placed 
onto  and  around  the  burner  to 
create a realistic look.  Bags of 
ceramic  fiber  embers  and  rock 
wool are provided. The ceramic 
fiber  comes  in  chunks  that  are 
about  2  inches  (5.1  cm)  long. 
Place  them  irregularly  around 
the  burner.  When  there  is  a 
sparse but even layer of embers, 
spread  the  rock  wool  in  the 
same manner.  
Figure 39.  Complete log set-up with embers.
WARNINGS: DO NOT pack this ember material as this could create an unsafe condition. The pieces 
should be lightly placed so they don’t block any of the burner ports. DO NOT allow any of the embers to 
rest against the pilot assembly.
Caution: Use only the type of ember material supplied with this fireplace. Due to the irregular size of 
the ember material, there may be more than required. Use of other foreign materials on the burners may 
create dangerous conditions. 
Figure 40. DV36 complete log set-up with embers burning.
it to cool down.  Then remove the glass and rearrange the ember material, making sure none of the 
burner ports are blocked.
Maintenance: Once a year, the logs should be removed and checked for deterioration or large amounts 
of soot.  A small amount on the bottom side of the logs is normal.  Remove and replace the logs in the 
same manner described above.
If new/more embers and rock wool are required, contact your nearest ENVIRO dealer.
Never operate the fireplace with the glass door removed.
Figure  40:  The  DV36 
burning  with  a  good 
flame.
NOTE:  While  the  glass 
is  still  removed,  it  is 
recommended  that  the 
gas  line  be  purged  by 
lighting the pilot.
When 
lighting 
the 
fireplace  for  the  first 
time  since  the  log  set 
and  embers  have  been 
installed/replaced,  watch 
for  ignition  at  ALL  the 
burner  ports.    If  a  long 
delay is noticed, turn the 
appliance off and wait for