Enviro DV36 用户手册

下载
页码 40
13
Maintenance And Service
8.  Reinstall the burner, brick panels, log set, embers, and glass door. 
Also refer to S
ECONDARY
 I
NSTALLATION
 - I
NSTALLING
 L
OG
 S
ET
 
AND
 E
MBERS
 
in your Owner’s Manual. When re-installing the burner, ensure that 
the burner to pilot hood relationship is similar to what is shown in 
Figure 14. On some units you will need to pay special attention when 
installing  the  burner  that  the  venturi  adjustment  rod  is  properly 
installed  into  the  venturi  adjustment  piece  welded  to  the  burner 
venturi tube
Figure 13: O-ring on valve screw.
9.  Reconnect the main gas line if it was disconnected and open the shut-off valve at the gas line to the 
unit.
10.  Use a small brush to apply a warm soapy water solution to all gas connections (use a half dish soap 
and half warm water). If a gas leak is present, bubbling will occur. Gas leaks can be repaired by 
using an approved pipe thread sealant or approved Teflon tape. NEVER USE AN OPEN FLAME WHEN 
TESTING FOR LEAKS.
11.  Reconnect the electrical power to the unit.
12.  Relight the main burner in both the “HI” and “LO” positions to verify proper burner ignition and 
operation and proper flame appearance. Also refer to S
ECONDARY
 I
NSTALLATION
 - I
NSTALLING
 L
OG
 S
ET
 
AND
 E
MBERS
 in your Owner’s Manual for a flame appearance picture. 
13.  MAKE SURE that the conversion label is installed on or close to the rating label to signify that the 
unit has been converted to a different fuel type. 
Figure 14. Ignitor assembly 
beside the burner.
g)  Re-attach the black protection 
cap that was removed in step 
a (Figure 10).