页码 39
through the outside wall far enough to connect onto the vent termination cap.
10. Apply a bead of Mill-Pac Black sealant to the top section of the Ø4” (10 cm) by 5” (12.5 cm) flue collar 
adaptor previously installed into the fireplace flue outlet.  Slide the Ø4” (10 cm) flex vent over the flue 
collar and secure with three (3) sheet metal screws evenly spaced.
11. Place a bead of high temperature silicone on the intake collar of the fireplace, slide the Ø65⁄8” (16.25 
cm) flex intake liner over the collar, secure the flex liner with three (3) sheet metal screws evenly 
spaced.
12. On the outside of the exterior wall, apply a bead of Mill-Pac Black sealant to the Ø4” (10 cm) pipe of 
the vent terminal.  Slide the flex liner onto the vent terminal and secure with three (3) sheet metal 
screws evenly spaced.
13. Place a bead of high temperature silicone on the intake collar of the vent terminal, slide the Ø65⁄8” 
(16.25 cm) flex intake liner over the collar, secure the flex liner with three (3) sheet metal screws 
evenly spaced.
14. Attach the vent terminal to the outside of the house using four (4) wood screws provided. 
15. Light the appliance and ensure proper operation.
O
THER
 A
PPROVED
 V
ENT
 P
ARTS
:
Table 3: Approved Vent Manufacturers
Manufacturer
Trade Name
Nominal Sizes
American Metal Products
AmeriVent Direct
4” - 6 5/8”
Security Chimneys International LTD
Secure Vent
4” - 6 5/8”
Selkirk Metalbestos
Direct-Temp
4” - 6 5/8”
Simpson Dura-Vent
Direct Vent GS
4” - 6 5/8”
The Retreat fireplace has been tested and certified for use with AMERICAN METAL PRODUCTS “AMERIVENT 
DIRECT”, SIMPSON DURAVENT TYPE GS PIPE FOR GAS STOVES.  SECURITY CHIMNEY’S “SECURE VENT 
DIRECT VENT SYSTEM” and SELKIRK “DIRECT-TEMP VENT SYSTEM” kits are available for horizontal and 
vertical venting.  When using Simpson Duravent, it is recommended that, before installation, a bead of 
RTV High Temperature Silicone should be applied to each outer vent joint, and Mil-Pac to each inner 
joint.  When planning an installation, it will be necessary to select the proper length of vent pipe for the 
particular requirements.  
WARNING: Do not mix parts from different vent manufacturers’s systems.
EXCEPTION  TO WARNING:    This product  has  been  evaluated by  Intertek  for  using a  Direct  Vent  GS 
starting collar in conjunction with Secure Vent, Direct-Temp, and Ameri Vent Direct venting systems.  Use 
of these systems with the Direct Vent GS starting collar is deemed acceptable and does not affect the 
Intertek WH listing of the appliance.
Initial Installation
QUALIFIED INSTALLERS ONLY