Enviro C-10794 用户手册

下载
页码 45
Maintenance And Service
TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY
F
UEL
 C
ONVERSION
:
Warning:  This conversion kit shall be installed by a qualified service agency in accordance 
with  the  manufacturer’s  instructions  and  all  applicable  codes  and  requirements 
of  the  authority  having  jurisdiction.  If  the  information  in  these  instructions  is  not 
followed  exactly,  a  fire,  explosion  or  production  of  carbon  monoxide  may  result 
causing property damage, personal injury or loss of life. The qualified service agency 
is responsible for the proper installation of this kit. The installation is not proper or 
complete until the operation of the converted appliance is checked as specified in the 
manufacturer’s instructions supplied with the kit.
Please read and follow these instructions. Also, please read the instruction guidelines provided by S.I.T. 
on how to remove and install the HI/LO regulator. 
Step 1.  Carefully inspect all parts supplied with this conversion kit.
Step 2.  Shut the gas supply off at the shut-off valve. (CAUTION: The gas supply shall be shut off prior 
to disconnecting the electrical power, before proceeding with the conversion.)
Step 3.  Remove the glass as shown in the M
AINTENANCE
 
AND
 S
ERVICE
 - O
PENING
 T
HE
 D
OOR
.
Using a 1⁄2" deep
socket remove/reinstall
the main burner orifice.
Undo the two
(2) screws that
hold burner in
the firebox.
Rotate handles
and remove the
door and glass.
Lift off the pilot
head and replace
with proper pilot
orifice for fuel type
to be used.
Venturi adjustment
bracket.
Pilot assembly moved
from firebox for clarity.
Figure 9: Unit burner shown apart.
10
Step 4.  Carefully remove the log 
set and ember material if 
they are installed.
Step 5.  Remove  the  two  (2) 
screws  (located  on  the 
outside  edges  of  the 
burner)  that  hold  the 
burner  to  the  chassis 
inside  the  fire  box,  see 
Figure  9.  Remove  the 
burner  tray  from  the 
firebox.
Step 6.  Change the regulator on 
the front of the gas valve 
(follow  the  instructions 
provided by S.I.T.).
Step 7.  To  change  the  pilot, 
simply pull the pilot hood 
straight up to access the 
pilot  injector.  Using  a 
5
/
32
 inch Allen key, remove 
the  pilot  injector  and 
replace  with  the  proper 
fuel type needed.