A  1  inch  (25  mm)  clearance  to  combustibles  must  be  maintained 
around  any  vertical  vent  pipe.  Around  a  horizontal  vent  pipe,  the 
clearance to combustibles should be 2 inches (50 mm) for rigid & 
33⁄8 inches (86 mm) for flex above, and 11⁄2 inches (38 mm) on the 
sides and bottom. When combustible materials are directly above 
a 90° elbow & above the unit, 8 inches (203 mm) of clearance are 
necessary; when not the elbow is not above the unit, 3 inches (76 
mm) for rigid pipe & 33⁄8 inches (86 mm) for flex pipe. A 10 inches 
(250 mm) x 10 inches (250 mm) frame (see Figure 35) will assure 
the proper support and spacing for a vent pipe through the ceiling 
or as it passes through the wall [up to 8 inches (203mm) for flex 
pipe].  Installations in Canada require that a wall thimble be used for 
passing through walls and ceilings. All sealing and vapour barriers 
must comply with local building codes.
When  planning  an  installation,  it  is  necessary  to  select  the 
proper  length  of  vent  pipe  for  the  particular  requirements.  The 
configuration of the venting pipes depends on the locations of walls, 
ceilings and studs. However, the pipes cannot be of arbitrary length 
and arrangement. Because the length of the vertical and horizontal 
sections dramatically affects the burning efficiency of the fireplace, 
Figure 35. Vent Framing Through the Wall or 
Ceiling.
Figure 34. Vent Pipe Clearances.
Initial Installation
QUALIFIED INSTALLERS ONLY
Table 7. Vent Pipe Minimum Clearances.
Vertical Pipe 
to the Side 
Walls
Horizontal Pipe 
to the Sides & 
Bottom
Above an 
Elbow Above 
the Unit
Above an Elbow 
Not Above the 
Unit
Above 
Horizontal Vent 
Pipe
Wall Frame  
8”(203mm) or 
less
Hard 
Pipe
1”
(25.4 mm)
11⁄2”
(38.1 mm)
8”
(203 mm)
3”
(76.2 mm)
2”
(51 mm)
10”x10”
(25x25cm)
Flex 
Pipe
1”
(25.4 mm)
11⁄2”
(38.1 mm)
8”
(203 mm)
3 3⁄8”
(86 mm)
3 3⁄8”
(86 mm)
10”x10”
(25x25cm)
2" (51mm)
8" (203mm)
46 1⁄4” (1175mm)
to a hard pipe
49 1⁄2” (1257mm)
to a flex pipe
Wall
Thimble
V
ENTING
:
This fireplace has been tested and certified for use with SIMPSON DURAVENT DIRECT VENT TYPE “GS” 
PIPE FOR GAS STOVES, SECURITY CHIMNEY’S SECURE VENT DIRECT VENT SYSTEM kits, AMERICAN 
METAL PRODUCTS AMERIVENT DIRECT and DIRECT-TEMP SELKIRK METALBESTOS.
certain  guidelines 
have  been  set  in 
I
NITIAL
 I
NSTALLATION
 
-  V
ENT
  C
ONFIGURA
-
TIONS
 
AND
  R
ESTRIC
-
TOR
 S
ETTINGS
Venting  terminals  cannot  be  recessed  into  a  wall  or 