Procom MN100TBA 用户手册

下载
页码 24
1 4
TROUBLESHOOTING
Note  :        All          troubleshooting
items    are    listed    in  order    of
operation.
    WARNING:  Only    a   qualified
service  person  should  service and
repair  heater.
   CAUTION:   Never  use  a  wire,
needle,  or  similar  object   to  clean
ODS/pilot.    This    can    damage
ODS/pilot  unit.
OBSERVED  PROBLEM
When  ignitor  button  is  pressed  in,
there  is  no  spark  at  ODS/pilot.
When   ignitor   button   is   pressed  in,
there  is  a  spark  at  ODS/pilot  but  no
ignition.
ODS/pilot    lights   but flame   goes out
when   control   knob is released.
POSSIBLE  CAUSE
1.   Ignitor electrode is positioned
      wrong.
2.   Ignitor electrode is broken.
3.   Ignitor electrode is not connected
      to  ignitor cable.
4.   Ignitor cable  is  pinched  or wet.
5.   Broken ignitor cable.
6.   Bad piezo ignitor.
1 . G a s   s u p p l y   t u r n e d   o f f   o r
    equipment  shutoff  valve is closed.
2.    Control  knob  not fully  pressed  in
       while  pressing  ignitor  button.
3.    Air  in  gas  lines  when  installed.
4.    ODS/pilot  is  clogged.
5.   Gas  regulator  setting is not cor-
       rect
6.   Control  knob  not in  PILOT  position.
1.   Control knob is not fully pressed
       in.
2.   Control  knob  is not  pressed  in
       long enough.
3.   Equipment  shutoff  valve  is not
       fully open.
4.   Thermocouple   connection   is
       loose at  control  valve.
5.  Thermocouple   damaged.
6.   Control valve   damaged.
REMEDY
1.   Replace ignitor.
2.   Replace ignitor.
3.   Reconnect ignitor cable.
4.   Free  ignitor  cable  if  pinched  by
       any       metal     or     tubing.    Keep
      ignitor   cable  dry.
5.   Replace  ignitor  cable.
6.   Replace  piezo ignitor.
1.   Turn    on    gas    supply    or   open
      equipment  shutoff  valve.
2.  Fully   press   in   control   knob
      while  pressing  ignitor  button.
3.   Continue   holding    down    control
knob.  Repeat  igniting  operation
      until  air  is  removed.
4.   Clean  ODS/pilot   (see    Cleaning
      and Maintenance Page  13)  or
replace  ODS/pilot  assembly.
5.   Replace  gas  regulator.
6.  Turn  control  knob    to    PILOT
position.
1.   Press in control knob fully.
2.   After  ODS/pilot lights, keep control
      knob  pressed  in  30  seconds.
3.    Fully  open equipment shutoff valve.
4.  Hand   tighten   until   snug,   then
      tighten 1/4  turn more.
5.   Replace   thermocouple.
6.   Contact Dealer or PRO-COM.