CAUTION:  Sharp  edges,  use  protective  gloves  when  
installing.
Tools Needed for Installation:
Sheet metal snips
5/16” nut driver
Phillips head screwdriver - #2
High temperature sealant or furnace cement rated for continuous use 
at 1,000
o
F minimum
Measuring tape
Parts Verification
See parts list on page 29 to verify components included in this vent 
kit prior to installation.
NOTE: If installing onto wood, lap, or vinyl siding, the vinyl siding 
kit should be used (sold separately, part number DV-822).
The vinyl siding vent kit, DV-822, is available from Empire Comfort 
Systems, Inc. The depth is 3” (76mm), which enables the vent cap to 
be extended away from vinyl siding or projections. The wall depth plus 
the additional 3” (76mm) depth of the vinyl siding vent cap extension 
should not exceed a total depth of 13 3/4” (349mm).
If  wall  depth  exceeds  13  3/4”  (349mm),  extend  system  using  
6 5/8” (168mm) x 4” (102mm) rigid venting (See Fireplace Instructions 
for approved lengths) See Figure 2.
Installing Wall Thimble/Firestop Assembly
1.  Fix fireplace to permanent location. If using rigid venting system, 
install up to the location where it will exit the building.
2.  Cut hole in wall for wall thimble/firestop assembly (Figure 1) into 
your combustible wall. Note: On brick or block exterior wall a 7” 
(178mm) diameter hole needs to be cut. 
  Measure the total wall thickness to determine whether or not the 
extension thimble is to be used.  If the combustible wall depth is 
over 5 3/8” (137mm), then the extension thimble should be used 
(Figure 1).
3.  Install the wall thimble assembly through the framed opening so the 
firestop plate is on the interior wall (Figure 1).  Telescope section 
should extend all the way through the exterior wall. Attach with 
(4) 10 x 1” screws.
4.  When placing the vent cap on an exterior wall covered with com-
bustibles such as wood, lap, or vinyl siding, install the  vinyl siding 
kit to the exterior wall sheathing.
Figure 1
Figure 2
Cutting Vent Tubes
This is the most important part of the installation.  With the 
fireplace (and the rigid venting system if used) fixed to its perma-
nent location, the 6 5/8” (168mm) diameter air inlet tube and the 
4” (102mm) diameter flue outlet tube are to be marked and cut 
using the following procedure.
5.  Attach  the  inlet  tube  to  the  outside  mounting  plate.  Align  
tinnerman clips on the tabs of the air inlet tube to the holes on 
outside mounting plate, and fix with (2) #10 x 1/2” screws.
6.  With the vinyl siding kit installed to wall (if necessary), insert the 6 
5/8” (168mm) diameter tube with outside mounting plate attached 
through hole in wall. Connect to collar on fireplace or rigid vent 
system. Measure between wall or vent cap extension and outside 
mounting plate (Figures 3A and 3B).
X
X = 13/3/4” MAX
TOTAL WALL THICKNESS
(SUBTRACT 3” IF USING THE
DV822 VINYL SIDING KIT)
½” AIR
SPACE
CLEARANCE
11”
9”
NOTE: SPACING FLANGE
INSTALLED TO TOPSIDE
INTERIOR WALL
EXTENSION
THIMBLE
DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS