7
veNtIlAtIoN AIR
Ventilation air from inside Building 
This fresh air would come from an adjoining 
unconfined  space.  When  ventilating  to  an 
adjoining unconfined space, you must provide 
two permanent openings: one within 12" of the 
ceiling and one within 12" of the floor on the 
wall connecting the two spaces (see options 
1 and 2, Figure 2). You can also remove door 
into adjoining room (see option 3, Figure 3). 
Follow  the  National  Fuel  Gas  Code, ANSI 
Z223.1/NFPA  54,  Air  for  Combustion  and 
Ventilation
  for  required  size  of  ventilation 
grills or ducts. 
AIR FOR COMBUSTION AND VENTILATION
Continued
Figure 3 - Ventilation Air from Outdoors
Figure 2 - Ventilation Air from Inside 
Building
ventilation Air From outdoors
Provide  extra  fresh  air  by  using  ventilation 
grills or ducts. You must provide two perma-
nent openings: one within 12" of the ceiling 
and one within 12" of the floor. Connect these 
items directly to the outdoors or spaces open 
to the outdoors. These spaces include attics 
and crawl spaces. Follow the National Fuel 
Gas  Code,  ANSI  Z223.1/NFPA  54,  Air  for 
Combustion and Ventilation
 for required size 
of ventilation grills or ducts.
IMPORTANT:  Do  not  provide  openings  for 
inlet or outlet air into attic if attic has a thermo-
stat-controlled power vent. Heated air entering 
the attic will activate the power vent.
INSTALLATION
Or 
Remove 
Door into 
Adjoining 
Room, 
Option 
Ventilation Grills  
Into Adjoining Room, 
Option 2 
Ventilation 
Grills  
Into Adjoining  
Room, 
Option 1 
12" 
12" 
Outlet 
Air 
Ventilated 
Attic  
Outlet 
Air 
Inlet 
Air 
Inlet Air 
Ventilated  
Crawl Space 
To 
Crawl
Space
To Attic 
 warninG: a qualified ser-
vice person must install firebox. 
follow all local codes.
 WARNING: Never install the 
firebox
•  in a bedroom or bathroom*
•  in a recreational vehicle
•  where curtains, furniture, cloth-
ing or other flammable objects 
are less than 42" from the front, 
top or sides of the firebox
•  in high traffic areas
•  in windy or drafty areas
* unless the installed log set is 
rated at 10,000 btu/hr or less 
in a bedroom or 6,000 Btu/Hr 
or less in a bathroom.
  Caution:  log  heaters 
installed  in  this  firebox  create 
warm  air  currents.  these  cur-
rents move heat to wall surfaces 
next to firebox. installing firebox 
next to vinyl or cloth wall cover-
ings or operating firebox where 
impurities  (such  as,  but  not 
limited to, tobacco smoke, aro-
matic candles, cleaning fluids, 
oil  or  kerosene  lamps,  etc.)  in 
the air exist, may discolor walls 
or cause odors.