Desa VSF20PT 用户手册

下载
页码 48
www.desatech.com
7
116307-01B
AIR FOR COMBUSTION 
AND VENTILATION
Continued
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills 
or ducts. You must provide two permanent open-
ings: one within 12" (30.4 cm) of the ceiling and 
one within 12" (30.4 cm) of the floor. Connect 
these  items  directly  to  the  outdoors  or  spaces 
open to the outdoors. These spaces include attics 
and crawl spaces. Follow the National Fuel Gas 
Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for 
Combustion and Ventilation for required size of 
ventilation grills or ducts.
IMPORTANT:
 Do not provide openings for inlet 
or outlet air into attic if attic has a thermostat-
controlled power vent. Heated air entering the attic 
will activate the power vent.
Figure 3 - Ventilation Air from Outdoors
Outlet
Air
Ventilated
Attic 
Outlet
Air
Inlet
Air
Inlet Air
Ventilated 
Crawl Space
To 
Crawl
Space
To Attic
INSTALLATION
NOTICE: This heater is intended 
for  use  as  supplemental  heat. 
Use this heater along with your 
primary heating system. Do not 
install  this  heater  as  your  pri-
mary heat source. If you have a 
central heating system, you may 
run system’s circulating blower 
while using heater. This will help 
circulate the heat throughout the 
house. In the event of a power 
outage, you can use this heater 
as your primary heat source.
 WARNING: A qualified ser-
vice person must install heater. 
Follow all local codes.
CHECK GAS TYPE
Use only the correct type of gas (natural or pro-
pane/LP). If your gas supply is not the correct gas 
type, do not install heater. Call dealer where you 
bought heater for proper type heater.
  WARNING:  This  appliance 
is equipped for (natural or pro-
pane/LP) gas. Field conversion 
is not permitted.
INSTALLATION ITEMS
Before installing heater, make sure you have the 
items listed below.
•  for propane/LP gas, external regulator (supplied 
by installer)
•  piping from gas supply (check local codes)
•  flex gas tubing
•  sealant (resistant to propane/LP gas)
•  equipment shutoff valve*
•  flex gas line with 3/8" NPT tap
•  ground joint union
•  sediment trap
•  tee joint
•  pipe wrench
•  for natural gas, test gauge connection*
* A CSA design-certified equipment shutoff valve 
with 1/8" NPT tap is an acceptable alternative to 
test gauge connection. The optional CSA design-
certified equipment shutoff valve can be purchased 
from your dealer. See Accessories, page 21.