BURNER FLAME PATTERN
 WARNING: If yellow tipping 
occurs, your heater could pro-
duce increased levels of carbon 
monoxide.
NOTICE: Do not mistake orange 
flames with yellow tipping. Dirt 
or other fine particles enter the 
heater  and  burn  causing  brief 
patches of orange flame.
Figure 24 shows a correct burner flame pat-
tern.  Figure  25  shows  an  incorrect  burner 
flame  pattern.  The  incorrect  burner  flame 
pattern  shows  yellow  tipping  of  the  flame. 
It also shows the flame higher than 1/2 the 
glass panel height.
If burner flame pattern is incorrect, as shown 
in Figure 25
•  turn  heater  off  (see  To  Turn  Off  Gas  To 
Appliance, page 16)
•  see Troubleshooting, page 19
INsPeCTING HeATeR
Check  pilot  flame  pattern  and  burner  flame 
pattern often.
PILOT FLAME PATTERN
Figure 22 shows a correct pilot flame pattern. 
Figure 23 shows an incorrect pilot flame pat-
tern. The incorrect pilot flame is not touching 
the thermocouple. This will cause the thermo-
couple to cool. When the thermocouple cools, 
the heater will shut down.
If  pilot  flame  pattern  is  incorrect,  as  shown 
in Figure 23
•  turn heater off (see To Turn Off Gas to Ap-
pliance, page 16)
•  see Troubleshooting, page 19
Note: The pilot flame on natural gas units will 
have a slight curve, but flame should be blue 
and have no yellow or orange color.
Figure 23 - Incorrect Pilot Flame Pattern
Figure 22 - Correct Pilot Flame Pattern
Thermocouple
Pilot Burner
Pilot 
Burner
Thermocouple
Blue Flame
Yellow Flame
Figure 24 - Correct Burner Flame Pattern 
Yellow 
Tipping
Figure 25 - Incorrect Burner Flame 
Pattern
1
/
 Glass 
Height
1
/
 Glass 
Height
Blue 
Flame