Electrical Requirements
Ground wire must be connected to the ground screw located in 
the lower right corner of the air conditioner when the air 
conditioner is in the cabinet.
The electrical ratings for your air conditioner are listed on the 
model and serial number label. The model and serial number 
label is located on the right-hand side of the air conditioner 
cabinet. 
Specific electrical requirements are listed in the chart below. 
Follow the requirements for the type of plug on the power supply 
cord.
Recommended Grounding Method
This air conditioner must be grounded. This air conditioner is 
equipped with a power supply cord having a grounded 3 prong 
plug. To minimize possible shock hazard, the cord must be 
plugged into a mating, grounded 3 prong outlet, grounded in 
accordance with all local codes and ordinances. If a mating outlet 
is not available, it is the customer's responsibility to have a 
properly grounded 3 prong outlet installed by a qualified electrical 
installer.
It is the customer's responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is adequate and in 
conformance with National Electrical Code, ANSI/NFPA 70 - 
latest edition, and all local codes and ordinances.
Copies of the standards listed may be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
Power Supply Cord
NOTE: Your air conditioner’s device may differ from the ones 
shown.
This room air conditioner is equipped with a power supply cord 
required by UL. This power supply cord contains state-of-the-art 
electronics that sense leakage current. If the cord is crushed, the 
electronics detect leakage current and power will be 
disconnected in a fraction of a second. 
Power Supply Cord
Wiring Requirements
115-volt (103.5 min. to 126.5 max.)
0 to 12 amps
15-amp time-delay fuse or 
circuit breaker
Use on single outlet circuit only.
230-volt (207 min. to 253 max.)
0 to 12 amps
15-amp time-delay fuse or 
circuit breaker
Use on single outlet circuit only.
230-volt (207 min. to 253 max.)
0 to 16 amps
20-amp time-delay fuse or 
circuit breaker
Use on single outlet circuit only.
230-volt (207 min. to 253 max.)
0 to 24 amps
30-amp time-delay fuse or 
circuit breaker
Use on single outlet circuit only.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING