Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Check the location where the air conditioner will be installed. 
Make sure you have everything necessary for correct installation.
The location should provide:
Heat/Cool Models—Grounded electrical outlet within 4 ft 
(122 cm) of where the power cord exits the air conditioner. 
Cool Only Models—Grounded electrical outlet within 6 ft 
(182.9 cm) of where the power cord exits the air conditioner.
NOTE: Do not use an extension cord.
Free movement of air in room to be cooled.
A large enough opening for the air conditioner. Installation 
parts are supplied for double-hung windows.
Adequate wall support for weight of air conditioner. Air 
conditioner weighs 88 lbs to 100 lbs (40 kg to 45 kg).
Window Installation 
Window opening measurements:
22
³⁄₄" min. to 32⁵⁄₈" max. (57.8 cm to 82.9 cm) opening width.
15" (38.1 cm) minimum opening height.
A. 22
³⁄₄
" min. (57.8 cm) 
B. 15" min. (38.1 cm) 
A
B
NOTES: 
Cabinet louvers must not be obstructed. Air must be able 
to pass freely through the cabinet louvers.
A. Cabinet louvers
Your model may differ from the one shown.
Electrical Requirements
Specific electrical requirements are listed in the chart below. 
Follow the requirements for the type of plug on the power supply 
cord.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING
Power supply cord 
Wiring requirements
115-volt (103.5 min. - 126.5 max.)
0-12 amps
15-amp time-delay fuse or 
circuit breaker
Use on single outlet circuit only.
The electrical ratings for your air conditioner are listed on the 
model and serial number label. The model and serial number 
label is located on the right-hand side of the air conditioner 
cabinet. 
A