Haier HSU-12HEG03/R2(DB) 用户手册

下载
页码 8
Operation
   Air Flow Direction Adjustment
Press FAN button. For each press, fan speed 
follows:
Remote controller:
Press
button
Every time the button is pressed, temp.setting
increase 1
o
C,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 1
o
C,if kept depressed, it will 
decrease  rapidly
Select a desired temperature.
4.Fan speed selection
3.Select temp.setting
Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to room
temperature.
1. Unit start
 Press ON/OFF on the remote controller, unit starts.
Base  Operation
Remote controller
1.Status display of air flow
When restart after remote turning off, the remote 
         memorize the previous 
Move the vertical blade by a knob on air
to adjust left and right direction referring to Fig.
2.Left and right air flow adjustment(manual)
Cautions:
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur 
adjusted to left or 
It is advisable not to keep horizontal flap at downward
position for a long time in COOLor DRY
otherwise, condensate water might occur.
conditioner
Emergency operation and test operation
at air outlet if all vertical louvers are 
right.
mode ,
controller will automatically
Note:
set swing position.
changes as
Operation
Mode
Remote
Controller
Note
In DRY mode , when room temperature becomes lower
than temp.setting+2
o
C, unit will run intermittently at LOW 
speed regardless of FAN setting. 
Under the mode of auto operation, air conditioner will
automatically select Cool or Heat operation according to
room temperature. When FAN is set to AUTO the air 
conditioner automatically adjusts the fan speed according
to room temperature.
In FAN operation mode , the unit will not operate in COOL or
HEAT mode  but only in  FAN mode, AUTO is not available in
FAN mode. And temp. setting is disabled. In FAN mode,
sleep operation is not available.  
Emergency Operation:
Use this operation only when the remote controller is defective 
or lost, and with function of emergency running, air conditoner
can run automatically for a while.
When the emergency operation switch is pressed, the " Pi "
sound is heard once, which means the start of this operation. 
When power switch is turning on for the first time and
emergency operation starts, the unit will run automatically in 
the following modes:
    Room
temperature
Designated
temperature
Timer
mode
Fan
speed
Operation
mode
  Above 23
o
C
  Below 23
o
C
 
23
o
C
 26
o
C
No
AUTO
AUTO
COOL
HEAT
No
It is impossible to change the settings of temp. and fan speed,It 
is also not possible to operate in timer or dry mode.
temperature is below 16
o
C, do not use it in the 
Test operation:
Use this switch in the test operation when the room
normal operation.
 your finger from the switch: the cooling
Continue to press the test operation 
switch for more than 5 seconds . After
 you hear the "Pi" sound twice, release
Test ope ration switch is the same as emergency switch.
operation starts with the air flow speed "Hi".
Under this operation mode,the fan motor of indoor
unit will run in high speed.
LOW
MED
HI
AUTO
2.
 
Select operation mode
COOL button:Cooling mode
HEAT button: Heating mode
DRY button: Dehumidify mode
Display 
circulated
DRY
COOL
AUTO
HEAT
FAN
In HEAT mode, warm air will blow out after a short 
period of the time due to cold-draft prevention function.
When FAN is set to AUTO, the air conditioner automatically 
adjusts the fan speed according to room temperature.
test operation
 switch
Pi
Pi
Pi
emergency
operation switch
'
2
Pos.1
Pos.2
Pos.3
Pos.4
Pos.5
Pos.6
(Auto swing)
cooling mode:from pos.1 to pos.4 and pos.6
heating mode:from pos.5 to pos.1 and pos.6