Haier HSU-12HC03/R2 用户手册

下载
页码 27
No
Reason of trouble
Phenomena
Remarks
1
The sensor  of  indoor  ambient
temperature is in short circuit or
broken circuit
The compressor indictor
and timing indicator
extinguish, and
the
running indicator   flickers
2
The temperature sensor of
indoor coil pipe is in short
circuit or broken circuit
The compressor indictor
and timing indicator are
on,
and
the
running
indicator  flickers
3
Theindoormotoris damaged,
or the
computer board is damaged
The power indicator and
running indicator of indoor
unit flicker twice , the power
indicator, running indicator
and timing indicator flicker
togetherfor 1 second,then
repeating the cycle.
The motor has no signal
feedback of Hall unit
 For the abnormal phenomenon occurred, please conduct trouble analysis and troubleshooting
according to the following table:
48
Domestic Air Conditioner
   Model: HSU-22HD03/R2