Haier HSU-09HSA03/R2(DB) 用户手册

下载
页码 90
Haier air conditioner
Edition: 20070116 
- 49 -
F1: The protection of IPM
Electrify the machine again and turn it 
on with the remote controller, then 
measure temperature on the module 
radiator and decide whether it is too 
high.
With a multimeter, test whether there 
is diode characteristic between the 
three terminals U/V/W and whether
the two terminals P/N of IPM module
and the diode characteristic is exist.
IPM Module might be poorly 
radiated and need to be recoated 
with heat conducting paste and 
reinstalled.
IPM Module is damaged and 
needs replacing.
The compressor should be 
damaged.
Yes
Yes
No
No
Test with a multimeter, and check
whether the resistance values among 
Phases U, V and W of compressor are 
equal and between 1 and 3O.
IPM Module is damaged and 
needs replacing.
No
Yes