Haier HSM12HRAC03/R2(DB) 用户手册

下载
页码 8
Trouble shooting
Normal
Performance
inspection
Noise is heard
Phenomenon
Cause or check points
The system 
immediately.
Smells are
generated.
Mist or steam are 
Multiple
check
Poor cooling
When unit is stopped, it won't restart 
elapsed to protect the system.
When the electric plug is pulled out 
and reinserted, the protection circuit 
During unit operation or at stop, 
a swishing or gurgling noise may 
(This noise is generated by
refrigerant flowing in the system.)
During unit operation, a cracking
noise may be heard.This noise is
temperature changes.
Should there be a big noise from
 filter may be too dirty.
This is because the system 
circulates smells from the interior
During COOL or DRY operation, 
This is due to the sudden cooling
Is power plug inserted?
Is there a power failure?
Is fuse blownout?
Is the air filter dirty?
Are there any obstacles before 
Is temperature set correctly?
Are there some doors or 
Is there any direct sunlight
through the window during the 
Are there too much heat sources
or too many people in the room 
In dry mode, fan 
speed can’t be 
changed.
In DRY mode, when room temperature
setting+2
o
C,unit will run
regardless of FAN setting.
during cooling operation?
cooling operation?(Use curtain)
 windows left open?
 inlet and outlet?
Normally it should be cleaned 
every 15 days.
intermittently at LOW speed 
becomes lower than temp.
indoor unit may blow out mist.
of indoor air.
air such as the smell of furniture,
paint, cigarettes.
air flow in unit operation, air 
generated by the casing expanding
or shrinking because of
be heard.At first 2-3 minutes after
unit start, this noise is more noticeable. 
will work for 3 minutes to protect the
air conditioner.
immediately until 3 minutes have
 Cautions
3. If the fuse of indoor unit on PC board is
it with the type of T. 3.15A/ 250V
outdoor
  broken,change it with the type of T.25A/250V
     Do not obstruct or cover the ventilation
conditoner.Do not put fingers
inlet/outlet and swing louver.
     Do not allow children to play with the air conditioner
case should children be allowed to sit on the outdoor unit.
The refrigerating circuit is leak-proof.
1.Applicable ambient temperature range:
 Specifications
The machine is adaptive in following situation
11 .The power plug and connecting cable
acquired the local 
2. If the power supply cord is damaged, it must be replaced 
manufacturer
qualified   person.
4. The wiring method should be in line with   the local wiring
5. After installation, the power plug should   be easily reached.
6. The waste battery should be disposed
   properly.
7. The appliance is not intended for use
 persons    without supervision.
8.Young children should be supervised
with
    the appliance.
9. Please employ the proper power plug,
cord.
12.In order to protect the units,please turn
30 seconds
     later, cutting off the power.
10. A breaker should be incorporated into
      should be
      contacts should be not less than
      3mm.
Cooling
Indoor
Maximum:D.B/W.B
Maximum:D.B/W.B
D.B
Maximum:D.B
D.B
Minimum:D.B/W.B
Maximum:D.B/W.B
Minimum:D.B/W.B
Outdoor
Indoor
Outdoor
Heating
32
o
C/23
o
C
24
o
C/18
o
C
o
C/-8
o
C
43
o
C/26
o
C
18
o
C
27
o
C
21
o
C/15
o
C
Outdoor
Maximum:D.B/W.B
Minimum:D.B
24
o
C/18
o
C
-15
o
C
(INVERTER)
0
o
C
7
-
13.Please don't insert any sensor on 3-way 
     stop valve pipe
Minimum:
Minimum:
grille of the air 
or any other things into the 
.In no
   or its service agent or a similar 
   broken,please
. If the fuse of 
standard.
by young children or
    to ensure that they
    which fit into the 
      fixed wiring. The 
      all-pole switch and the distance 
must have
     off the A/C first, 
 fitting. 
Before asking for service, check the following 
first.
blown out.
does not restart
by the 
change
unit is
infirm
do not play
    power supply 
      breaker 
      between
      its two 
attestation.
and at least 
X
0.415
0.317
HSU-09HRA103/R2
HSU-12HRA103/R2