Johnson Controls 13 SEER 用户手册

下载
页码 12
347337-UIM-A-0408
10
Johnson Controls Unitary Products
 FIGURE 12:  Thermostat Chart - Single Stage AC with PSC Furnace
AC 5E
Single Stage Air Conditioner – Single Stage PSC Furnace
C
24 – Volt Common
Y
Compressor Contactor
SINGLE STAGE
AIR
CONDITIONER
SINGLE STAGE
AIR CONDITIONER
Y
Full Stage Compressor
G
Fan
*BP11C50124
*BN11C01124
*DP11C40124
*DN11C00124
THERMOSTAT
RH
24 – Volt Hot
(Heat XFMR)
RC
24 – Volt Hot
(Cool XFMR)
W
Full Stage Heat
Selection of GAS/ELEC 
switch on thermostat
is not necessary
C
24 – Volt Common
Y
Full Stage Compressor
G
Fan
*BN11C00124
THERMOSTAT
RH
24 – Volt Hot
(Heat XFMR)
RC
24 – Volt Hot
(Cool XFMR)
W
Full Stage Heat
Thermostat Installer Setup
1-System Type-must be 
set to 0
C
24 – Volt Common
Thermostat Installer Setup
15-Compressor Protection
must be set to 5
External Humidistat
(Optional)
Open on Humidity Rise
G8C
L(Y/M)8S
G*9F
G*(8/9)S
ID MODELS
(G/T)GLS
TG(8/9)S
LF8
GF(8/9)
C
24 – Volt Common
R
24 – Volt Hot
W
Full Stage Heat
SINGLE STAGE PSC
FURNACE 
G
Fan
 SINGLE STAGE
PSC
FURNACE 
Other Part Numbers:
SAP   =    Legacy
265901  =  031-09166
1
1
24VAC Humidifier
(Optional)
2
 Part Number:
S1-2HU16700124
2
Y/Y2
Full Stage Compressor