WARNING
7.  INSTALLATION INSTRUCTIONS
7-1.  Installation Site Selection
7-1-1.  Indoor Unit
To prevent abnormal heat 
generation and the possibility 
of fire, do not place obstacles, 
enclosures and grilles in front 
of or surrounding the air 
conditioner in a way that may 
block air flow.
For stable operation of 
the air conditioner, do not 
install wall-mounted type 
indoor units less than 
1.5 m from floor level.
AVOID:
direct sunlight.
nearby heat sources that may affect performance of 
the unit.
areas where leakage of flammable gas may be 
expected.
places where large amounts of oil mist exist.
DO:
select an appropriate position from which every corner 
of the room can be uniformly cooled. (High on a wall 
is best.)
select a location that will hold the weight of the unit.
select a location where tubing and drain hose have 
the shortest run to the outside.
allow room for operation and maintenance as well as 
unrestricted air flow around the unit. (Fig. 1)
install the unit within the maximum elevation 
difference (H) above or below the outdoor unit and 
within a total tubing length (L) from the outdoor unit as 
detailed in Table 1 and Fig. 2.
Install the indoor unit more than 1 meter away from 
any antenna or power lines or connecting wires used 
for television, radio, telephone, security system, or 
intercom. Electrical noise from any of these sources 
may affect operation.
Table 1
Model
KRV94 / 124
* If total tubing length becomes 7.5 to 15 m, charge additional refrigerant (R410A) by 15 g/m.
  No additional charge of compressor oil is necessary.
Max. Allowable Tubing
Length at Shipment
(m) 
7.5
Limit of Tubing
Length (L)
(m) 
15
Limit of Elevation
Difference (H)
(m)
10
Required Amount of 
Additional Refrigerant
(g/m)*
15
5 cm
min.
5 cm
min.
15 cm min.
Front View
INDOOR
UNIT
Tubing length (L)
OUTDOOR
UNIT
Elevation
difference (H)
CAUTION
Indoor unit
Floor level
Wall
Minimum height 
from floor level
1.5 m
Fig. 1
Fig. 2
Fig. 3
22