Sanyo SAP-KRV94EHDX 用户手册

下载
页码 85
Emergency operation
SENSOR DRY
AUTO cooling/heating operation
Selecting the operation mode
During DRY operation, the system adjusts the room 
temperature and fan speed according to the conditions in the 
room, in order to maintain a comfortable room environment.
SENSOR DRY operation
DRY operation is as shown in the figure below.
PAM-   control
  In order to further improve inverter performance, control is 
switched between PWM control at low operation speeds, and 
PAM control at high operation speeds, making the most 
effective use of power.
The compressor operation frequency varies.
The indoor fan operates with 1/f fluctuation.
The compressor operates at a low operating frequency.
The indoor fan operates with 1/f fluctuation.
  Monitoring operation takes place when the room temperature 
is below 15  C, or more than 3  C below the set temperature.
  When the monitoring range is entered, the compressor stops, 
and the indoor fan operates with 1/f fluctuation.
DRY A
DRY B
Monitor
Conditions are monitored at all 
times when the room temperature 
is below 15  C.
Load
COOL zone
A zone
B zone
Emergency operation is available when the remote 
controller malfunctions, has been lost, or otherwise 
cannot be used.
  The set temperature is 2  C below the detected room 
temperature in the case of cooling operation, and 2  C 
above the room temperature in the case of heating 
operation. The flap and fan speed settings are AUTO.
(GREEN) (RED)
(Lamp 
Off)
COOL
HEAT
STOP
  When AUTO mode is selected, the microprocessor calculates 
the difference between the set temperature and the room 
temperature, and automatically switches to Cooling or 
Heating mode.
  As shown by the example in the figure below, with AUTO 
cooling/heating operation, the mode changes between 
Heating and Cooling mode according to changes in the 
relationship between the current room temperature and the 
set temperature.
Room temp.    Set temp.      COOL
Room temp.    Set temp.      HEAT
23
Zone A
Zone B
Zone C
Zone C
Zone B
Zone A
OFF
OFF
Compressor
Operation mode
Room temp.
Heating
Cooling
Cooling
ON
ON
ON
More than
1 hour
Within
1 hour
Set temp.
Example
Example of operation in AUTO mode with the set room temperature 
at 23  C.
To operate the system, press the OPERATION button, 
which is also used as the receiver, below the unit display. 
Each time this button is pressed, the OPERATION lamp 
changes color to indicate the type of operation. Select the 
desired type of operation.
The Sensor Dry operation during the Low Ambient Cooling 
Mode (outside air temperature:15  C or lower) is as follows. 
The compressor operates a cycle of 3 minutes ON and 6 
minutes OFF repeatedly.
NOTE
DRY A
DRY B
and
9.  FUNCTIONS
9-1.  Operation Functions
39