Sanyo SAP-KRV94EHDX 用户手册

下载
页码 85
8
2-2.  Major Component Specifications
2-2-1.  Indoor Unit
Indoor Unit
SAP-KRV94EHDX
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Over-Heat Protection
 Micro F
VAC
-
Yes
Yes
-
Internal Controller
Aluminum Plate Fin / Copper Tube
2
1.1
 Face Area
m
2
0.272
 Coil
 Rows
 Fin Pitch
mm
 Heat Exchanger Coil
Microprocessor
 250V 3.15A
 Control Circuit Fuse
 Controls
1 ... D100 / L677
RCS-4HVPDXS4EE
 Fan
Cross-Flow
 Remote Control Unit
 (Ambient Temp. 25
o
C )
Each Pair of Terminal : 70 +/- 7%
 Control PCB
CB-KRV94EHDX
 Part No.
 Fan Motor
-
MP24Z2
DC 5V
 Coil Resistance
Ohm
For Left Flap
MP24Z2
 Safety Device
 Rating
Type
 Model
For Right Flap
For Upper Flap
For Lower Flap
Over- Current Protection
 (Ambient Temp. 20
o
C)
 Nominal Output
W
 Coil Resistance
Ohm
mm
 Type
30
1,200 / 1,200
 Model ... Q'ty
 No. of Poles
SIC-39CVL-D847-3 ... 1
8
 Flap Motor
 Type
Stepping Motor
 Rough Measure RPM (Cool / Heat )
 Run Capacitor
 Type
DC Motor
 Q'ty ... Dia. and Length
 Panel Motor
 Type
Stepping Motor
 Model
MP35EA
 (Ambient Temp. 25
o
C)
MP24Z5
MP24Z1
 Rating
DC 12V
 Coil Resistance
Ohm
Each Pair of Terminal : 130 +/- 7%