Friedrich EM24 用户手册

下载
页码 56
18
920-198-00
Troubleshooting tips
Power failure
If you have a power failure, the unit's auto-restart feature will resume 
operation in the selected mode prior to the power failure.
Won't cool?
If your air conditioner operates, but won’t cool; check to see if the controls 
are properly set. Check the filter and clean thoroughly if needed. Check 
to see if the vent door is closed. Check to see if the chassis seal gasket is 
installed (refer to installation instructions).
Won't run?
Make sure the power cord is plugged in completely. Check for a bad fuse, 
tripped breaker or tripped LCDI Device. Refer to page 3 for LCDI reset 
instructions and to confi rm proper fuse size. 
For QuietMaster Programmable models only:
You can reset the circuit board by pressing the “Moneysaver” button and 
the “Check Filter” button at the same time. The LED (small red light) for 
the Check Filter will begin blinking. Once this occurs, turn the unit off by 
pressing the On/Off button once and then unplug the unit. Finally, plug the 
unit back in and turn it on by pressing the On/Off button once. All settings 
revert back to the factory default settings.
This is a warm weather appliance
Your air conditioner is designed to cool in warm weather when the outside 
temperature is above 60°F (16°C) and below 115°F (46°C), so it won't 
cool a room if it is already cool outside. 
If you want to cool a room in the 
spring or fall, touch 
Fan Only
 and set the 
Fresh Air/Exhaust
 control to 
Fresh Air
. This will bring in a supply of cooler outside air.
Condensation is normal
Air conditioners actually pump the heat and humidity from your room to the 
outside air. Humidity be comes water, and your air conditioner will use most 
of the water to keep the outside coil cool. If there is excessive humidity, there 
may be excess water that will drip outside. This is normal op er a tion.
Frosting
This usually occurs because of insufficient airflow across the coils, a dirty 
filter, cool damp weath er, or all of these. Set unit to Fan Only and the frost 
will disappear. Setting the thermostat a little warmer will probably prevent 
the frosting from recurring.
Noises
All air conditioners make some noise. Friedrich QuietMaster
®
 units are 
designed to operate as quietly as possible. An air conditioner mounted in 
a wall is quieter than one mounted in a window. It is important to ensure 
that the chassis seal gasket is properly installed (refer to installation 
instructions).
Cleaning your air conditioner
The decorative front and the cabinet can be cleaned with warm water and 
a mild liquid de ter gent. The indoor coil can be vacuumed with a dusting 
attachment if it appears to be dirty. The outdoor coil can be gently sprayed 
with a hose if you can get to it. If not, you might call your dealer for a 
more thorough cleaning when needed. The air fi lter should be inspected 
weekly and cleaned if needed by vacuuming with a dust attachment or by 
cleaning in the sink using warm water and a mild dishwashing detergent. 
Dry the fi lter thoroughly before reinstalling. Use caution– the coil surface 
can be sharp.
Heat pumps operate differently
If your unit is a "Y", or heat pump model, there are some things that you 
will want to be aware of.
Some functions of a heat pump differ from your unit when it is used for 
heating:
1.  It is normal for ice to form on the outdoor coil of the heat pump. 
Moisture in the outside air, passing over the coil when very cold, 
will form ice.
2.  If the outdoor temperature drops below 37°F (3°C), your heat pump 
will automatically turn on the electric re sis tance heat. When the 
temperature rises to 40°F (4°C), the compressor will resume the 
heat pump operation. If your unit is a 115 volt model (YS09), it is 
designed for use in warmer climates and has no electrical heat 
feature, and will not provide adequate heat below 37°F (3°C).
Available Accessories
DC Drain Kit - Part No. 01900235
In some installations, excess condensate water caused by extremely humid 
con di tions, may result in an un de sir able water drip such as on a patio or 
over an entryway. MODEL DC-2 DRAIN KIT (Part No. 01900-235) can be 
installed to drain the excess condensate.
Window Installation Kits
TwinTemp or Heat/Cool room air conditioners are shipped without window 
mount ing hard ware because they are seldom mount ed in the window. For 
those in stanc es when these units are being mounted in a window, there 
are window installation kits available. Depending upon the chassis size for 
which an in stal la tion kit is desired, order:
• 
WIKS for Small Chassis (ES, YS models)
• 
WIKM for Medium Chassis (EM, YM models)
• 
WIKL for Large Chassis (EL, YL models)
THESE ACCESSORIES CAN BE ORDERED FROM YOUR FRIEDRICH DEAL ER.