Friedrich SS08M10 用户手册

下载
页码 132
39
WARNING
Electrical Shock Hazard
Make sure your electrical receptacle has the
same configuration as your air conditioner’s
plug. If different, consult a Licensed Electrician.
Do not use plug adapters.
Do not use an extension cord.
Do not remove ground prong.
Always plug into a grounded 3 prong oulet.
Failure to follow these instructions can result in
death, fire, or electrical shock.
Routine Maintenance
monthly, and more frequently if conditions warrant.  The unit must be turned 
To Remove, Wash and Replace Filter
Coils & Chassis
NOTE: 
  .
n
a
p
 
e
s
a
b
 
r
o
 
s
li
o
c
 
n
o
 t
n
e
g
a
 
g
n
i
n
a
e
l
c
 l
i
o
c
 
c
it
s
u
a
c
 
a
 
e
s
u
 t
o
n
 
o
D
Use a biodegradable cleaning agent and degreaser.  The use 
of  harsh  cleaning  materials  may  lead  to  deterioration  of  the 
The  indoor  coil  and  outdoor  coils  and  base  pan  should  be  inspected 
periodically (annually or semi-annually) and cleaned of all debris (lint, dirt, 
leaves, paper, etc.) as necessary.  Under extreme conditions, more frequent 
cleaning may be required.  Clean the coils and base pan with a soft brush 
and compressed air or vacuum.  A pressure washer may also be used, 
pack when pressure cleaning coils.
NOTE:  It  is  extremely  important  to  insure  that  none  of  the  electrical 
and/or electronic parts of the unit get wet.  Be sure to cover all 
electrical components to protect them from water or spray.
Decorative Front
Use a damp (not wet) cloth when cleaning the control area to prevent 
water from entering the unit, and possibly damaging the electronic control.
The decorative front and the cabinet can be cleaned with warm water 
and a mild liquid detergent.  Do NOT use solvents or hydrocarbon based 
cleaners such as acetone, naphtha, gasoline, benzene, etc.  
The indoor coil can be vacuumed with a dusting attachment if it appears 
to be dirty.  DO NOT BEND FINS.  The outdoor coil can be gently 
sprayed with a hose if you can get to it.  If not, you might call your dealer 
for a more thorough cleaning when needed.  
vacuuming with a dust attachment or by cleaning in the sink using warm 
reinstalling.  Use caution the coil surface can be sharp.
Fan Motor & Compressor
The fan motor & compressor are permanently lubricated, and require no 
additional lubrication.
Wall Sleeve
Inspect the inside of the wall sleeve and drain system periodically (annually 
or semi-annually) and clean as required.  Under extreme conditions, more 
frequent cleaning may be necessary.  Clean both of these areas with an 
antibacterial  and  antifungal  cleaner.    Rinse  both  items  thoroughly  with 
water and ensure that the drain outlets are operating correctly.  Check the 
sealant around the sleeve and reseal areas as needed.
Service and Assistance
Before calling for service, please check the “Troubleshooting Tips” section 
avoid unnecessary service calls, and save you the cost of a service call 
if the problem is not due to the product itself.  If you have checked the 
“Basic Troubleshooting” section and still need help, it is available as follows:
our web site at www.friedrich.com.
If you require further assistance
You can call the Customer Support Call Center at 1-800-541-6645.
Before calling, please make sure that you have the complete model and 
serial  number,  and  date  of  purchase  of  your  equipment  available.    By 
providing us with this information, we will be better able to assist you.
Our specialists are able to assist you with:

u  Referrals to dealers, and distributors.
u  Use and Care Information.
u  Recommended maintenance procedures.
u  Installation information.
u  Referrals to Authorized Service Providers and Parts depots.
Available Accessories
DC-2 Drain Kit – Part No. 01900235
In some installations, excess condensate water caused by extremely humid 
conditions, may result in an undesirable water drip such as on a patio or 
over an entryway.  MODEL DC-2 DRAIN KIT (Part No. 01900-235) can be 
installed to drain excess condensation to an alternate location.
Carbon Filter Kits
The kits vary depending on the chassis size (small, medium, large).  Each 
WCFS
WCFM
WCFL
Remote Wall Thermostats
RT4 – Digital wall thermostat hard wired with single speed fan.
RT5 – Digital wall thermostat hard wired with two fan speed selection, 
battery backup and backlight display.
Window Installation Kits (Standard in Kühl  
Models without Heat)
KWIKS  – For all ES and YS models.
KWIKM – For all EM and YM models.
KWIKL – For all EL and YL models.
See www.friedrich.com for additional accessories for your unit.