Operation 
6
311628C
Operation
On/Off switch lever (8d) is located under nozzle holder. 
Remove nozzle before turning pump on.
1.
Move switch lever (8d) on.
2.
Insert nozzle into tank and actuate nozzle lever to 
dispense herbicide.
3.
Immediately after dispensing herbicide turn switch 
lever (8d) off.
Maintenance
1.
Clean inlet strainer (3b) after every 50 hours of 
operation.
2.
To remove inlet strainer (3b), remove four screws 
(3c) and strainer cover (3a). Remove and clean 
strainer.
3.
If strainer is excessively dirty, clean tank to protect 
pump and the equipment.
4.
After cleaning strainer, replace strainer and cover. 
Make sure cover seal (3d) is in place.
Flushing Pump
Proper flushing of pump after use with herbicides and 
chemicals is essential for long service life. Many herbi-
cides dry quickly and will make pump inoperative if 
allowed to dry inside pump.
1.
Remove pump from tank and insert suction tube into 
water or chemical agent recommended by chemical 
manufacturer.
2.
Operate pump until fluid discharge is free of chemi-
cal.
3.
For extended storage after use with herbicide or 
chemical, flush pump and fill with diesel fuel.
Before servicing, turn pump off and open the 
nozzle to relieve pressure.
CAUTION
Do not operate pump dry. Do not run pump for more 
than 5 minutes with nozzle closed. Do not operate 
pump for more than 30 minutes continuously in 1 hour.
CAUTION
All fluids pumped must be compatible with wetted 
parts listed on page 12.