RECOMMENDED TUBE  DIAMETERS
 
* For tube sets greater than 50 ft horizontal and/or 20 ft vertical differential, consult Residential Split System Application Guideline and Service Manual.
 
CHECK-FLO-RATER® PISTON
 
*Piston listed is for any approved non-capillary tube coil com-
bination. Piston is shipped with outdoor unit and must be 
installed in an approved indoor coil.
 
 
 
UNIT
SIZE
Liquid Tube Diameter (In.)
Vapor Tube Diameter (In.)
0 to 50 Ft
Tube Length
Long-Line Applications*
0 to 50 Ft
Tube Length
Long-Line Applications*
(Maximum Diameter)
 
024
3/8
3/8
5/8
7/8
030, 036
3/4
7/8
042, 048
7/8
1-1/8
060
1-1/8
1-1/8
 
UNIT SIZE–SERIES
PISTON*
IDENTIFICATION NO.
 
024-G
55
030-F
63
036-F, G
70
042-F
73
048-F
78
060-H
TXV
  
M
A
N
U
F
A
C
T
U
R
E
R
CE
RT
IFIED
TO ARI
AS
C
O
M
P
L
Y
IN
G
W
IT
H
A
RI
STANDARD
21
0
U
N
IT
A
R
Y
AIR
CO
N
D
IT
IO
N
IN
G
EQUIPMENT
REGISTERED
ISO 9001:2000
 
CERTIFICATION APPLIES ONLY
WHEN THE COMPLETE SYSTEM
IS LISTED WITH ARI.
REGISTERED QUALITY SYSTEM
 
As an ENERGY STAR® 
partner, Bryant Heating & 
Cooling Systems has 
determined that this prod-
uct meets the ENERGY 
STAR® guidelines for 
energy efficiency.
 
 
*
 
*Refer to the combination ratings in the Product Data Sheet for system combinations meeting ENERGY STAR® efficiency standards.
 
CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE*)
 
* Must be a Puron® approved hard shutoff TXV.
 
UNIT SIZE–SERIES
REQUIRED SUBCOOLING (°F)
 
024-G
10
030-F
12
036-F, G
11
042-F
12
048-F
11
060-H
12
 
MODEL NUMBER NOMENCLATURE
 
550A
N
X
024
Model Number
 
13 SEER Split-System  
Air Conditioner
N/A
 
Electrical Supply
N
 
 – 208/230-1-60 
 
Nominal Cooling Capacity
024
 
 – 2 ton      
 
042
 
 – 3.5 ton
 
030
 
 – 2.5 ton   
 
048
 
 – 4 ton
 
036
 
 – 3 ton      
 
060
 
 – 5 ton
 
000
A
A
AA
 
Standard Unit
 
Series A
 
 – Original Series
 
Series B
 
 – Second Series, etc.
 
Common Unit
 
 – U.S.A. Only
 
Heating Size