Raypak 751-1501 产品宣传页
Catalog No.: 2000.36G
Effective: 2-1-08
Replaces: 5-1-05
Job:
Engineer:
Contractor:
Prepared By:
Date:
Model:
Indoor/Outdoor:
100% Factory Fire Tested
Efficiency: 84%
Maximum Outlet Temperature: 230°F
Minimum Non-Condensing Inlet Temperature: 105°F
Thermal Shock Proof Heat Exchanger
Footprint: Less Than 5-1/2 ft
2
Limited Twenty-Year Thermal Shock Warranty
Limited Ten-Year Heat Exchanger Warranty
Ten-Year Unconditional Burner Head Warranty
Operation Status Center and Full Diagnostic Panel
Heat Exchanger
Bronze Headers
ASME Inspected and Stamped
Bronze Headers
ASME Inspected and Stamped
160 PSIG Working Pressure
National Board Approved
Copper-finned Tubes
ASME Steel Tube Retainer
Silicone High Temp O-Rings
60 PSIG ASME Pressure Relief
Copper-finned Tubes
ASME Steel Tube Retainer
Silicone High Temp O-Rings
60 PSIG ASME Pressure Relief
Valve
Temperature and Pressure Gauge,
Shipped Loose
Control
120V, 60Hz, Power Supply
120/24V 60Hz Transformer
100% Pilot Shutoff/Lockout
Electronic Intermittent Ignition Pilot
120V, 60Hz, Power Supply
120/24V 60Hz Transformer
100% Pilot Shutoff/Lockout
Electronic Intermittent Ignition Pilot
(IID)
High Limit Control, Manual Reset
High Limit Control, Auto Reset
On/Off Switch
Flow Switch
Blocked Vent Pressure Switch
Combustion Air Proving Switch
Time Delay Pump Off Control
High Limit Control, Auto Reset
On/Off Switch
Flow Switch
Blocked Vent Pressure Switch
Combustion Air Proving Switch
Time Delay Pump Off Control
Central Point Wiring Diagnostics
Panel
Burner
Aerodynamically Stabilized
Aerodynamically Stabilized
Non-Clog Burner
Ultra-Low NOx: Less than 30 PPM
Gas Train
Fuel
Fuel
Natural Gas
Propane (Models 751 & 1001)
Propane (Models 751 & 1001)
Manual Gas Shut-off Valves
Gas Pressure Regulator
Safety Shut-off Valve
Firing Control Valve
Manual Low Gas Pressure Switch
On/Off Firing Mode (H4)
Design Certified ANSI Z21.13/
Gas Pressure Regulator
Safety Shut-off Valve
Firing Control Valve
Manual Low Gas Pressure Switch
On/Off Firing Mode (H4)
Design Certified ANSI Z21.13/
CSA 4.9
Construction
Indoor/Outdoor Construction
Front Controls Enclosed
PolyTuf Powder Coat Finish
Connections (Water, Electrical,
Indoor/Outdoor Construction
Front Controls Enclosed
PolyTuf Powder Coat Finish
Connections (Water, Electrical,
Gas)
Rear – Standard
Right Side – Option A-8
Right Side – Option A-8
Venting
Vent Location
Vent Location
Rear – Standard
Right Side – Option Z-2
Right Side – Option Z-2
Vent Termination Cap
Outdoor - Option D-11
Indoor, Horizontal – Option D-15
Indoor, Vertical (by others)
Indoor, Horizontal – Option D-15
Indoor, Vertical (by others)
Temperature Controls
B-20
Single-Stage Controller,
100-200°F
100-200°F
B-6
2-Stage Controller, 100-200°F
B-21
4-Stage TempTracker Digital
Controller, Loose
Controller, Loose
B-23
4-Stage TempTracker Digital
Controller, Outdoor Reset, Loose
Controller, Outdoor Reset, Loose
Y-241 Electronic Sequencer,
1-4 Stages
Y-281 Electronic Sequencer,
5-8 Stages
Additional Safety Controls (Optional)
F-10
Low Water Cut-off,
Remote Probe
Remote Probe
S-2
Manual High Gas Pressure
Switch
Switch
Regulatory Agency Requirements
C-5
Ignition Lockout Module
Other Equipment
Condensing Heat Exchanger
Pump
ADB™ - Type H
Hydronic Heating Boilers
Models 751-1501