Catalog No.:  2000.36G 
Effective:  2-1-08  
Replaces:  5-1-05
 
Job: 
 
           
 
Engineer: 
 
           
 
Contractor: 
 
           
 
Prepared By: 
            
 Date:
             
 
Model:  
         
 
 Indoor/Outdoor:   
         
 
   
 
 
100% Factory Fire Tested  
Efficiency: 84% 
Maximum Outlet Temperature: 230°F 
Minimum Non-Condensing Inlet Temperature: 105°F 
Thermal Shock Proof Heat Exchanger 
Footprint: Less Than 5-1/2 ft
2
 
Limited Twenty-Year Thermal Shock Warranty 
Limited Ten-Year Heat Exchanger Warranty 
Ten-Year Unconditional Burner Head Warranty 
Operation Status Center and Full Diagnostic Panel 
 
 
Heat Exchanger 
ƒ  Bronze Headers   
ƒ  ASME Inspected and Stamped 
160 PSIG Working Pressure 
ƒ  National Board Approved 
ƒ Copper-finned Tubes 
ƒ  ASME Steel Tube Retainer 
ƒ  Silicone High Temp O-Rings 
ƒ  60 PSIG ASME Pressure Relief 
Valve 
ƒ  Temperature and Pressure Gauge, 
Shipped Loose 
Control 
ƒ  120V, 60Hz, Power Supply 
ƒ  120/24V 60Hz Transformer 
ƒ  100% Pilot Shutoff/Lockout 
ƒ  Electronic Intermittent Ignition Pilot 
(IID) 
ƒ  High Limit Control, Manual Reset 
ƒ  High Limit Control, Auto Reset 
ƒ On/Off Switch 
ƒ Flow Switch 
ƒ  Blocked Vent Pressure Switch 
ƒ  Combustion Air Proving Switch 
ƒ  Time Delay Pump Off Control 
 
ƒ  Central Point Wiring Diagnostics 
Panel 
Burner 
ƒ Aerodynamically Stabilized 
Non-Clog  Burner  
ƒ  Ultra-Low NOx: Less than 30 PPM 
Gas Train  
ƒ Fuel 
 Natural Gas 
 Propane (Models 751 & 1001) 
ƒ  Manual Gas Shut-off Valves 
ƒ Gas Pressure Regulator 
ƒ  Safety Shut-off Valve 
ƒ Firing Control Valve 
ƒ  Manual Low Gas Pressure Switch 
ƒ  On/Off Firing Mode (H4) 
ƒ  Design Certified ANSI Z21.13/ 
CSA 4.9 
Construction 
ƒ Indoor/Outdoor Construction 
ƒ Front Controls Enclosed 
ƒ  PolyTuf Powder Coat Finish 
ƒ  Connections (Water, Electrical, 
Gas) 
 Rear – Standard 
 Right Side – Option A-8 
Venting 
ƒ Vent Location 
 Rear – Standard  
 Right Side – Option Z-2 
ƒ  Vent Termination Cap 
 Outdoor - Option D-11 
 Indoor, Horizontal – Option D-15 
 Indoor, Vertical (by others) 
Temperature Controls 
 B-20 
Single-Stage Controller,  
100-200°F 
 B-6 
2-Stage Controller, 100-200°F 
 B-21 
4-Stage TempTracker Digital 
Controller, Loose 
 B-23 
4-Stage TempTracker Digital 
Controller, Outdoor Reset, Loose 
 Y-241  Electronic Sequencer,  
1-4 Stages 
 Y-281  Electronic Sequencer,  
5-8 Stages 
Additional Safety Controls (Optional) 
 F-10 
Low Water Cut-off,  
Remote Probe 
 S-2 
Manual High Gas Pressure 
Switch 
                        
 
                        
 
Regulatory Agency Requirements 
 C-5 
Ignition Lockout Module 
                        
 
Other Equipment 
 Condensing Heat Exchanger 
 
Pump    
 
 
 
 
 
 
ADB™ - Type H
Hydronic Heating Boilers
Models 751-1501