Raypak 302BE-902BE 产品宣传页

下载
页码 2
Catalog No.: 
 
2000.441E 
Effective:  11-15-07 
Replaces:  1-1-07  
 
Hi Delta – Type H 
Models 302BE-902BE, 87% Efficiency
 Model 
           
 
 
 
 
 
 
 
 
 
RATES OF FLOW AND PRESSURE DROPS
 
10°F 
T 20°F 
T
30°F 
T
Min. Flow
Max. Flow 
Model GPM 
P (ft) 
GPM 
P (ft) 
GPM 
P (ft) 
GPM 
P (ft) 
GPM 
P (ft) 
302BE 52  3.4  26  <1
N/A
N/A
20
<1
26
90
9.8 6 
402BE 
69 5.8 35 1.5 23  <1  20  <1 35 
90 10.0 
502BE 
87 9.9 44 2.5 29 1.2 22  <1 40 
90 10.5 
10 
652BE 
N/A 
 
N/A 57 4.3 38 2.0 28 1.2 
40 
90 10.7 
13 
752BE 
N/A 
N/A 
 65 5.8 44 2.7 33 1.7 
40 
90 11.0 
15 
902BE 
N/A N/A 78 9.0 52 4.1 39 2.4 
40 
90 11.8 
17 
Basis is 20 GPM or 40°F 
∆T for minimum flow, 90 GPM for maximum flow.
 
NOTE: Pump location 
varies based on model 
and application 
NOTES:  1.  Rates shown are for natural or propane gas, and elevations up to 5,000 feet. For installation above 5,000 feet, please contact manufacturer. 
 
2.  Required natural gas pressure is 7 – 10.5” WC. Required propane gas pressure is 11 – 13” WC.
 
SPECIFICATIONS 
 
 
 
Approx.
MBTUH
A
G H 
K T  W
Amp. Shipping
Model
Input Output Width NPT NPT     
 
Draw Wt. 
(Lbs)
302BE
300
261
36
3/4 2 5 
6  18
6
380
402BE
399 347  43 3/4 2 
18-1/2
6  445 
502BE
500 435  50 
1-1/4 
6 22  6  545 
652BE
650 566 
60-1/2 1-1/4 
27-1/4
6  590 
752BE
750 653 
67-1/2 1-1/4 
30-3/4
6  675 
902BE
900 783  78 
1-1/4 
6 36  7  740 
Dimensions are in inches. 
Raypak, Inc.  