Burnham MST513 用户手册

下载
页码 64
4
WARNING
This boiler contains very hot water under high pressure.  Do not unscrew any pipe fittings nor attempt 
to disconnect any components of this boiler without positively assuring the water is cool and has no 
pressure.  Always wear protective clothing and equipment when installing, starting up or servicing this 
boiler to prevent scald injuries.  Do not rely on the pressure and temperature gauges to determine the 
temperature and pressure of the boiler.  This boiler contains components which become very hot when 
the boiler is operating.  Do not touch any components unless they are cool.
This boiler must be properly vented.  The chimney must be inspected for any obstructions and cleaned 
prior to each heating season. A clean and unobstructed chimney flue is necessary to produce the minimum 
draft required to safely evacuate noxious fumes that could cause personal injury or loss of life.  Evidence 
of loose debris and or condensate induced stains at the base of the chimney flue, connector or smokepipe 
joints may be signs of condensing flue gases.  Flue gas condensate is corrosive, which requires special 
consideration and must be addressed immediately.  Refer to Section V, "Venting and Air Intake Piping".
This boiler needs fresh air for safe operation and must be installed so there are provisions for adequate 
combustion and ventilation air.
This boiler is supplied with controls which may cause the boiler to shut down and not re-start without 
service.  If damage due to frozen pipes is a possibility, the heating system should not be left unattended in 
cold weather; or appropriate safeguards and alarms should be installed on the heating system to prevent 
damage if the boiler is inoperative.
This boiler is designed to burn No.  fuel oil only.  Do not use gasoline, crankcase drainings, or any oil 
containing gasoline.  Never burn garbage or paper in this boiler.  Do not convert to any solid fuel (i.e. 
wood, coal). Do not convert to any gaseous fuel (i.e. natural gas, LP).  All flammable debris, rags, paper, 
wood scraps, etc., should be kept clear of the boiler at all times.  Keep the boiler area clean and free of 
fire hazards.
All boilers equipped with burner swing door have a potential hazard which, if ignored, can cause severe 
property damage, personal injury or loss of life.  Before opening swing door, unplug burner power cord 
from receptacle located in lower right corner of jacket front panel and turn off service switch to boiler 
to prevent accidental firing of burner outside the combustion chamber.  Be sure to tighten swing door 
fasteners completely when service is completed.
TABLE OF CONTENTS
  I.  Pre-Installation . . . . . . . . . . . . . . . . . . . .     7
 VII.  Oil Piping . . . . . . . . . . . . . . . . . . . . . . .   37
 II.  Unit-Pak Boiler Assy  . . . . . . . . . . . . . . .     9
VIII.  System Start-Up . . . . . . . . . . . . . . . . . .   39
III.  Steam Boiler Trim & Piping . . . . . . . . . . .  22
 IX.  Maintenance & Service Instructions  . . .   45
IV.  Tankless & Indirect Water Heater Piping .  24
  X.  Boiler Cleaning . . . . . . . . . . . . . . . . . . .    48
 V.  Venting & Air Intake Piping . . . . . . . . . .   27
 XI.  Trouble Shooting . . . . . . .  . . . . . . . . . .    50
VI.  Electrical  . . . . . . . . . . . . . . . . . . . . . . . .   32
XII.  Repair Parts . . . . . . . . . . . . . . . . . . . . .    51