*Note: A chimney approved to ULC standard S629 in Canada or UL 103HT in the U.S. must be used to connect the smokepipe at 
the top of the cabinet to maintain the 2” (5.08cm) clearance to combustibles. The approved chimney must extend 1” (2.54cm) below 
the heatshield. PLEASE NOTE: That these are factory recommended clearances only, and are subject to local, provincial or state 
building and fire codes. These clearances may change without notice
Chart of Clearances
When a heat shield is installed dimensions B, D, E and F are taken from 
the heat shield.
Dimensions A, C, G, and H  remain the same with or with-out a heat 
shield. 
Dimensions A and C are taken from the reservoir  on reservoir models.
When two or more clearances to combustible walls contradict each other, 
the clearance with the greater numerical value must  be maintained.
Status Model A B C D E F G H J Measure
NO HEAT
SHIELD
SweetHeart
25
69
66
66
50
58
132
61
121
Centimeters
10
27
26
26
20
23
52
24
48
Inches
Oval
25
68
66
91
50
86
132
61
121
Centimeters
10
27
26
36
20
34
52
24
48
Inches
WITH HEAT
SHIELD
SweetHeart
25
8
66
61
5
31
132
61
121
Centimeters
10
3
26
24
2
12½
52
24
48
Inches
Oval
25
8
66
91
5
44
132
61
121
Centimeters
10
3
26
36
2
17½
52
24
48
Inches