Hotpoint GB 750 X 用户手册

下载
页码 16
GB
6
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
Electrical 
connections
DATA PLATE
see data plate
This appliance conforms to the following 
European Economic Community directives:
- 2006/95/EEC dated 12/12/06 (Low 
Voltage) and subsequent amendments
- 2004/108/EEC dated 15/12/04 
(Electromagnetic Compatibility) and 
subsequent amendments
- 93/68/EEC dated 22/07/93 and 
subsequent amendments.
- 2009/142/EEC dated 30/11/09 (Gas) and 
subsequent amendments.
- 2002/96/EC and subsequent 
amendments.
Table 1                                                                                     Liquid Gas                                                  Natural Gas 
Burner                        Diameter     Thermal      Thermal    By-pass    Nozzle           Flow*              Thermal     Nozzle        Flow*
                                                       power          power       1/100       1/100             (g/h)                 power       1/100         (l/h)
                                                          kW               kW                                                                          kW
                                                      (p.c.s.*)       (p.c.s.*)                                                                  (p.c.s.*)
                                      (mm)       Reduced     Nominal     (mm)       (mm)         ***          **          Nominal       (mm)
Supply pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
Reduced Fast (RR)
Semi Fast (S)
Auxiliary (A)
Triple Crown (TC)
Ultrarapid (UR)
Semi-Fishburner (SP)
Double Flame
(DCDR Internal) (2)
Double Flame
(DCDR External)
2 nozzle (2)
100
75
55
130
100
30
130
0.70
0.40
0.40
1.50
0.70
0.70
0.40
1.50
2.60
1.65
1.00
3.30
3.40
1.50
0.90
4.10
39
28
28
61
39
39
28
61
80
64
50
65x2
91
60
44
70x2
189
120
73
240
247
109
65
298
186
118
71
236
243
107
64
293
2.60
1.65
1.00
3.60
3.40
1.50
0.90
4.10
122 (H)
96 (Y)
79 (6)
103x2
138 (H)
88
70
114x2
248
157
95
343
324
143
86
390
Double flame
(DCDR internal) (1)
30
0,30
0,90
27
44
65
64
0,90
69
86
Double
flame (1)
(DCDR 
internal)
(DCDR 
external
2 nozzle)
130
1,50
4,60
27
44
334
329
5,00
69
476
55
70 x 2
113 x 2
Burner and nozzle specifications (for 75 cm versions only)
(1) For single-control DRDA (DCDR) burner only
(2) For dual-control DRDA (DCDR) burner only
At 15°C and 1013 mbar - dry gas
** 
Propane P.C.S. = 50.37 MJ/Kg
*** 
Butane  P.C.S. = 49.47 MJ/Kg
 
Natural  P.C.S. = 37.78 MJ/m³