Burner Inlet Orifi ce Sizes:
 
                   NG 
       LPG
 
Burner  
 #32 
       #50 
 
 
2.95mm      1.78mm
 
            
Max. Input  NG 40 
Mj/h
  
LPG 
38 
Mj/h
Min. Input  NG 20 
Mj/h
  
LPG 
19 
Mj/h
  
Supply Pressure   
 
NG 
min.  1.13 kPa
 
LPG 
min. 2.75 kPa
Manifold Pressure
 NG 
.94 
kPa 
 LPG 
2.55kPa 
Electrical: 240 V. 1.13A  60Hz.
Circulation: 2 speed fan, 125/75 CFM.
Log Set: Ceramic fi ber, 7 per set.
System Data
F39 Converted to 31mj
Burner Inlet Orifi ce Sizes:
 
NG 
#37   2.65mm
 
LPG 
#52   1.6mm
Max. Input - NG/LPG
  
31 
Mj/h 
Min. Input - NG/LPG
  
16 
Mj/h
Supply Pressure   
 
NG 
min.  1.13 kPa
 
LPG 
min. 2.75 kPa
Manifold Pressure
 NG 
.89 
kPa 
 LPG 
2.55kPa 
Electrical: 240 V. 1.13A  60Hz.
Circulation: Variable speed fan, 125/75 
CFM.
Log Set: Ceramic fi ber, 7 per set.
System Data
F39 with 40mj
INSTALLATION
Note:    To properly check gas pressure, both 
inlet and manifold pressures should 
be checked using the valve pressure 
ports on the valve.
1)  Make sure the valve is in the "OFF" posi-
tion.
2)  Loosen the "IN" and/or "OUT" pressure 
tap(s), turning counterclockwise with a 1/8" 
wide fl at screwdriver.
3)  Attach manometer to "IN" and/or "OUT" 
pressure tap(s) using a 5/16" ID hose.
4)  Light the pilot and turn the valve to "ON" 
position. Read manometer.
5)  The pressure check should be carried out 
with the unit burning and the setting should 
be within the limits specifi ed on the safety 
label.
6)  When fi nished reading manometer, turn 
off the gas valve, disconnect the hose and 
tighten the screw (clockwise) with a 1/8" fl at 
screwdriver. Note: Screw should be snug, 
but do not over tighten
Valve Description
1) Gas 
on/off 
knob
2)  Manual high/low adjustment
3) Pilot 
Adjustment
4) Thermocouple 
Connection
5) Main 
Operator
6)  Outlet Pressure Tap (Manifold 
 Pressure)
7) Inlet 
Pressure 
Tap 
(Supply 
 Pressure)
8) Pilot 
Outlet
9)  Main Gas Outlet
10) Flange Securing Screw Holes
11) Alternative TC Connection Point
12) Thermoelectric Unit
13) Additional Valve Mounting Hole
AERATION 
ADJUSTMENT
The burner aeration is factory set but may need 
adjusting due to either the local gas supply or 
altitude.
 
 
     F39 with 40mj
F39-NG 
NG:  
Full open
F39-LPG 
LPG:  
Full open
                     F39 with 31mj
F39-NG NG 
6mm 
open
F39-LPG LPG 
10mm 
open
Note: Any 
damage due to carboning resulting 
from improperly setting the aeration 
controls is NOT covered under war-
ranty.