Regency F38-2 Freestanding Gas Stove
OPERATING INSTRUCTIONS
4)  Turn the PILOT knob counterclockwise to 
pilot and align it with the arrow as shown 
in diagram 1.
5)  Push in PILOT knob all the way in and hold. 
Immediately push IGNITOR button until pilot 
lights. Continue to hold the PILOT knob in 
for  approximately one minute, then release 
the PILOT  knob.  The pilot fl ame  should 
continue to burn.  If the pilot does not remain 
lit, repeat operation allowing a longer period 
before releasing PILOT knob.
6)  Turn PILOT knob counter clockwise to 
on.
7)  Use the ON/OFF switch to turn on the 
burner.
8)  Rotate the HEAT control to adjust the fl ame 
height higher or lower.
SHUTDOWN 
INSTRUCTIONS
  1) Use the ON/OFF switch, wall switch, 
thermostat or remote control to turn off the 
burner.
  2) Push in the PILOT knob slightly and turn 
clockwise to off. Do not force.
  3) Turn off all electric power to the appliance 
if service is to be performed.
FIRST FIRE
The FIRST FIRE in your heater is part of the 
paint curing process. To ensure that the paint 
is properly cured, it is recommended that you 
burn your fi replace for at least four (4) hours the 
fi rst time you use it with the fan on. 
When  fi rst operated, the unit will release an 
odour caused by the curing of the paint and the 
burning off of any oils remaining from manufac-
turing. Smoke detectors in the house may go 
off at this time. Open a few windows to ventilate 
the room for a couple of hours. The glass may 
require cleaning.
DO NOT ATTEMPT TO CLEAN THE GLASS 
WHILE IT IS STILL HOT!
Note:  When the glass is cold and the appli-
ance is lit, it may cause condensation 
and fog the glass. This condensation 
is normal and will disappear in a few 
minutes as the glass heats up.
DO NOT BURN THE APPLIANCE 
WITHOUT THE GLASS FRONT IN 
PLACE.
OPERATING 
INSTRUCTIONS 
Before operating this appliance, proceed through 
the following check list.
1)  Read and understand these Instructions 
before operating this appliance.
2)  Check to see that all wiring is correct and 
enclosed to prevent possible shock.
3)  Check to ensure there are no gas leaks.
4)  Make sure the three pieces of door glass 
are properly positioned.  Never operate the 
appliance with any of the glass removed or 
with the door open.
5)  Verify that all fl ueing and the cap is unob-
structed.
6)  Verify log placement. If the pilot cannot be 
seen when lighting the unit - the logs or the 
embers have been incorrectly positioned.
7)  The unit should never to turned off and on 
without a minimum of a 60 second wait.
LIGHTING 
INSTRUCTIONS
IMPORTANT:  The PILOT knob cannot be 
turned from pilot to off unless it is partially 
depressed.
Note:  Open the pedestal door of the unit 
before lighting the pilot. Once the 
pilot is lit, close the door.  You should 
never operate the unit with the door 
open.
1)  If the PILOT knob is in the off position 
proceed to  Step 4.
Diagram 1
2)  Push in PILOT knob slightly and turn clock-
wise to off.  Knob cannot be turned from 
pilot to off unless knob is pushed in slightly.  
Do not force.
  
3) Wait 
fi ve minutes to allow gas, that may have 
accumulated in the main burner compart-
ment, to escape. If you smell gas, follow 
the instructions on the front of this manual. 
If you don't smell gas continue on to the next 
step.
DO NOT BURN THE APPLIANCE 
WITHOUT THE GLASS FRONT IN 
PLACE.
WARNING
DO NOT SPRAY AEROSOLS IN 
THE VICINITY OF THIS
 APPLIANCE WHILE IN 
OPERATION
ADJUSTING FLAME 
HEIGHT
 
Your heater has an adjustable fl ame to tailor the 
look and heat output to your specifi c needs. It 
is adjusted by turning the fl ame adjustment dial 
on the gas control valve.
Turn clockwise to adjust the fl ame higher, coun-
terclockwise for a lower fl ame.
AUTOMATIC 
CONVECTION 
FAN OPERATION
Set the fan speed on  
control panel at the 
top rear of the unit  to 
adjust to the desired 
speed. The fan will 
turn on as the stove 
comes up to operating 
temperature. After the 
unit has been turned 
off and the unit cooled 
to below a useful heat 
output range the fan 
will shut off automati-
cally.