Regency F38-LPG2 用户手册

下载
页码 23
Regency F38-2 Freestanding Gas Heater
17
MAINTENANCE
CLOTHING OR OTHER FLAMMA-
BLE MATERIAL SHOULD NOT BE 
PLACED ON OR NEAR THE AP-
PLIANCE.
DO NOT USE THIS APPLIANCE 
IF ANY PART HAS BEEN UNDER 
WATER. IMMEDIATELY CALL AN 
AUTHORIZED SERVICE TECHNI-
CIAN TO INSPECT THE APPLIANCE 
AND TO REPLACE ANY PART OF 
CONTROL SYSTEM AND ANY GAS 
CONTROL WHICH HAS BEEN UN-
DER WATER.
6)  Verify proper operation after servicing.
WARNING: CHILDREN AND ADULTS 
SHOULD BE ALERTED TO THE 
HAZARDS OF HIGH SURFACE 
TEMPERATURE AND  SHOULD 
STAY AWAY TO AVOID BURNS 
OR CLOTHING IGNITION.  YOUNG 
CHILDREN SHOULD BE CARE-
FULLY SUPERVISED WHEN THEY 
ARE IN THE SAME ROOM AS THE 
APPLIANCE.
CAUTION:  ANY SAFETY SCREEN 
OR GUARD REMOVED FOR SERV-
ICING AN APPLIANCE MUST BE 
REPLACED PRIOR TO OPERATING 
THE APPLIANCE
.
MAINTENANCE 
INSTRUCTIONS
 1)  Always shut the valve off before cleaning. 
For relighting, refer to lighting instructions. 
Keep the burner and control compartment 
clean by brushing and vacuuming at least 
once a year. When cleaning the logs, use 
a soft clean brush as the logs are fragile 
and easily damaged.
2)  Clean glass (never when unit is hot), appli-
ance, louvres, and door with a damp cloth.  
Never use an abrasive cleaner. The gold 
louvres (and optional gold door) may be 
scratched if abrasives are used to clean 
them.
 
The heater is fi nished in a heat resistant 
paint and should only be refi nished  with 
heat resistant paint (not with wall paint). 
Regency uses StoveBright Paint - Metallic 
Black #6309.
3)  Make a  periodic check of burner for proper 
position and condition. Visually check the 
fl ame of the burner periodically, making sure 
the fl ames are steady; not lifting or fl oating. 
If there is a problem, call an authorized 
service person. 
4)  The appliance and fl ueing system must be 
inspected before use, and at least annu-
ally, by an authorized fi eld service person, 
to ensure that the fl ow of combustion and 
ventilation air is not obstructed. 
 
During the annual service call, the burners 
should be removed from the burner tray 
and cleaned. Replace the embers - do not 
block the pilot or burner ports.
5)  Keep the area near the appliance clear and 
free from combustible materials, gasoline 
and other fl ammable 
 
vapours and liquids.
LOG REPLACEMENT
The unit should never be used with broken logs. 
Turn off the gas valve and allow the unit to cool 
before opening door to carefully remove the 
logs. The pilot light generates enough heat to 
burn someone. If for any reason a log should 
need replacement, you must use the proper 
replacement log. The position of these logs 
must be as shown in the diagram under Log 
Installation.  
Note: Improper positioning of logs may cre-
ate carbon build-up and will alter 
the unit’s performance which is not 
covered under warranty.
DOOR AND 
GLASS GASKET
 
If the door gasket requires replacement use 
7/8" diameter oval door gasket (Part # 650-920). 
The glass requires 5/8" fl at glass gasket. See 
your Regency dealer.
GLASS 
REPLACEMENT
Your Regency heater is supplied with high 
temperature, 5mm Neoceram silica coated 
ceramic glass that will withstand the highest 
heat that your unit will produce. In the event 
that you break your glass, purchase your re-
placement from an authorized Regency dealer 
only, and follow the step-by-step instructions 
for replacement.
Removing Glass:
Note: Wearing gloves will protect your 
hands while handling glass.
1)  Remove the door from the unit and place 
on a soft surface to prevent scratching.
2)  Pull out the door gasket.
3)  Remove the 24 nuts holding the glass 
retainers in place. Do not remove the nuts 
underneath the retainers.
4)  Remove the door catch plate.
5)  Remove glass retainers on sides fi rst (3 each 
side) then remove two center retainers.
6)  Remove glass from door assembly. When 
removing glass, leave white insulation in 
place.
7)  Reverse steps 6 to 2.
Safety Screen: Only required in Australia