Pipe Length
Round Support
Box/Wall Thimble
(Part # 940)
Round
Support Box/
Wall Thimble
(Part # 940)
Vertical
Terminal
Storm Collar
Part # 953
Flashing
943 or 943S
Ceiling Firestop
(Part # 963)
24" (610mm)
Pipe Length
Adj.Pipe Length
11" - 14-5/8"
(279mm - 372mm)
90 Elbow
o
Wall Thimble
Part # 942
Vinyl Siding
Standoff (Optional)
Part #950
AstroCap
Termination Cap
(Part# 946-523)
DURA-FLUE 
TERMINATION KIT
Planning Your Dura-Flue 
Installation
There are two basic types of Dura-Flue Room 
Sealed System installations: horizontal termi-
nation and vertical termination. Confi rm the 
maximum horizontal run and maximum vertical 
rise from the diagrams, refer to "Fluing Arrange-
ments" section. 
When planning your installation, it will be nec-
essary to select the proper length of fl ue pipe 
for your particular requirements. For horizontal 
installations, determine the minimum clearance 
from the rear of the unit to the wall. It is also 
important to note the wall thickness.  (The wall 
thimble is suitable for 2 x 4 or 2 x 6 wall construc-
tion.) Select the amount of vertical rise desired 
for "vertical-to-horizontal" type installations.  
Warning:  Always maintain required clear-
ances (air spaces) to nearby combustibles 
to prevent a fi re hazard. Do not fi ll air spaces 
with insulation. 
The minimum clearance requirements between 
the outer wall of the fl ue pipe and nearby com-
bustible surfaces is 1-1/4 inch. Be sure to check 
the fl ue termination clearance requirements 
from decks, windows, soffi ts, gas regulators, air 
supply inlets and public walkways as specifi ed 
in the Exterior Flue Terminal Locations on page 
8 and in your local building codes.
To determine the length of fl ue pipe required 
for vertical installations, measure the distance 
from the unit fl ue outlet to the ceiling, the ceiling 
thickness, the vertical rise in an attic or second 
storey, and allow for suffi cient vertical height 
above the roof line. 
For multi-storey applications, fi re stops are 
required at each fl oor level. If an offset is 
needed, additional pipe, elbows and supports 
will be required.
Do not exceed the maximum number of elbows.  
One 90
o
 for horizontal terminations and two 45
o
 
for vertical termination.
DURA-FLUE FLUING 
COMPONENTS
You will require the following components with 
your new Regency
®
 Room Sealed Freestand-
ing Gas Stove. Please review your product to 
make sure you have everything you need. In 
the efl ue that you are missing any part, contact 
your dealer. 
Note: 
These are the minimum pieces re-
quired. Other parts may be required 
for your particular installation. See 
page 12 for a list of fl ue parts.
If installing termination on a siding covered wall, 
a vinyl siding standoff or furring strips can be 
used in order to ensure that the termination is 
not recessed into siding.
The vinyl siding standoff is required for walls 
with vinyl siding.
Minimum components for a Dura-Flue 
Horizontal 
Installation:
 
A) Dura-Flue 
Horizontal 
Termination 
Kit
B)  Wall Thimble (required  for combus-
 tible 
walls)
Minimum components for a Dura-Flue Verti-
cal Termination:
C) Dura-Flue 
Vertical 
Termination 
Kit
 
See page 12 for pipe lengths.
The Simpson Dura-Flue Room Sealed System 
offers a complete line of component parts for 
installation of both horizontal and vertical installa-
tion. Many items are offered in decorative black, 
as well as galvanized fi nish. The galvanized pipe 
INSTALLATION
and fi ttings are used for concealed locations 
such as attics or where corrosion is a factor, 
such as above the roof line. Decorative brass 
trim kits are available for both wall thimbles and 
ceiling support boxes.  
Part # 
  Description
971 Horiz. 
Termination 
Kit 
includes: 
90
 
black elbow, wall thimble cover, 
 
horiz. square termination cap, 
24" 
 
black pipe, 11" -14" 5/8" adjust-
able 
 
black  pipe 
970 Basic 
Horiz. 
Termination 
Kit 
 includes: 
 
90
o
 black elbow, wall 
 
thimble cover, horiz.  square 
 termination 
cap
978 Vert. 
Termination 
Kit 
includes 
 
0/12 -  6/12 pitch adjustable 
 
fl ashing, storm  collar, low profi le
 term. 
cap
908B 
6" Pipe Length-Black 
907B 
9" Pipe Length-Black 
906 
12" Pipe Length Galv.
906B 
12" Pipe Length-Black  
904 
24" Pipe Length Galv.
904B 
24" Pipe Length-Black 
903 
36" Pipe Length Galv. 
903B 
36" Pipe Length-Black 
902 
48" Pipe Length Galv.
902B 
48" Pipe Length-Black 
911B 
11"-14 5/8" Adj. Pipe Length-
Black 
917B 
17"- 24" Adj. Pipe Length Black 
945 45
Elbow Galv.
Dura-Flue Basic 
Horizontal Kit # 970
1 90
o
 Elbow
1 Wall Thimble Cover
1 Astro Cap